Owner's Manual

44
MAINTENANCE
Battery Replacement
1. Remove the spark plug wire from spark plug.
2. Loosen and remove the nuts on the battery hold-
down plate and remove the plate from the support
rods (see Figure 58).
1
2
3
Figure 58
1 - Nuts
2 - Battery Hold-
Down Plate
3 - Support Rods
3. Tip the battery forward slightly to access battery
cables.
4. Disconnect the black negative (-) battery cable from
the battery first.
5. Disconnect the red positive (+) battery cable
second and remove the battery.
1
2
Figure 59
1 - Red Positive (+)
Battery Cable
2 - Black Negative (-)
Battery Cable
NOTICE
Dispose of the used battery properly according to
the guidelines established by your local or state
government.
6. Install the new battery into the generator frame.
7. Connect the red positive (+) battery cable to the
battery first.
8. Connect the black negative (-) battery cable to the
battery second.
9. Install the battery hold-down plate using the nuts
removed in step 2.
10. Install the spark plug wire onto spark plug.
The battery for 10KPRO, Part No. 100170, is the same
as a wheelchair batter
y.
Type Sealed lead-acid
Model LA-12V20-NB
Volts 12
Amp 21
Dimensions (L x H x W) 7.13 x 3 x 6.63 in.
(18.1 x 7.6 x 16.8 cm)