• i SEER:EnergyefcientbrushlessDC(ECM)motorgives
upto1SEERpointefciencygainincooling.
• 100% fired and tested:Allunitsandeachcomponent
aretestedonthemanufacturingline.
• Best packaging in the industry: Uniquecornerpost
designassuresproductwillarrivetothehomeownerdent
free.
• 30 second blower delay:Atstart-upassuresawarm
ducttemperatureatfurnacestart-up.Adjustableblower
offsettings(60,90,120and180seconds).
• 30 second post purge: Increases life of heat
exchanger.
• Hot surface igniter: Innovative application of a
silicon nitride type igniter. Utilizes proven Smartlite
®
technology.
• Color coded wire harness: Designed to fit the
components,all withquick-connectttings foreaseof
serviceandreplacement.
• Flexible category IV venting system: May be
vertically or horizontallyventedusing either a one-pipe
ortwo-pipesystemformaximumexibilityininstallation.
• High Static Blowers: All models equipped with high
staticblowers.
• Low Boy Height:Easytoapplyinlowceilingapplications,
workswellwithtallerhighSEERcoils,easiertohandle
andinstall.
• Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger and stainless steel
secondaryheatexchangerassuresalonglife.
• 90 second fixed cooling cycle blower-off delay (TDR):
Increases cooling performance when matched with a
NORDYNEcoil.
• Variable speed blower kit:Upgradabletofullvariable
speedwithkit.
• LP convertible:Simpleburneroriceandregulatorspring
changeforeaseofconvertibility.
• Diagnostic lights for easy troubleshooting without
counting flashes:Dedicatedlightforamesignalstrength
and2lightsincombinationtoindicateallotherfaultcodes
witheasytorecognizestateswithoutcountingashes.
• Incorporates integrated control board: With
connectionsforelectronicaircleanerandhumidier.
• Two piece door design:Enhancesfurnaceappearance
andusescapturedscrewstopreventlosingdoorscrews.
• Blower Compartment:Sealeddoortoreduceairleakage
andinsulatedforultraquietoperation.
• Sealed Vestibule:Reducesburnerandinducersound
levels.
• 2 Stage Inducer:Optimizesefciencyonrststageheat
andreducessoundlevels.
Induced Draft - 95.1 AFUE
Input 60,000 - 120,000 Btuh
FG7T (C and L Series)
Two Stage, Fixed Speed ECM,
High Efficiency Upflow/Horizontal
and Downflow Gas Furnaces
Thehighefciencyupowgasfurnacemaybeinstalledfree
standinginautilityroom,basement,orenclosedinanalcove
orcloset.Upow/horizontalunitscomereadyforupowor
horizontalapplication.Theextendedushjacketprovidesa
pleasing“applianceappearance.DesigncertiedbyCSA
forapplicationinCanadaandtheUnitedStates.
FEATURES and BENEFITS
TECHNICAL
SPECIFICATIONS
,
Smartlite
®

Summary of content (8 pages)