User manual


Gas Connection
Before commencing installation, check to ensure the type
of gas to which the appliance is intended to be connected
matches the gas type given on the appliance data plate.
Check the data plate (located behind the oven door) to
determine gas type. A gas type label is located on the back
panel near the gas inlet.
A 1700mm long flexible hose is supplied in the pack for
installation purposes.
Connecting flexible hose
Place a spanner on the flats provided on the gas inlet
to brace the inlet against the action of wrenching when
connecting the hose to the appliance gas inlet. Failure to
do so may damage the appliance.
An approved thread sealing tape or compound is
required for the connection between the hose and the
appliance gas inlet.
Appliances for operation on N.G. & S.N.G.
For N.G. and S.N.G appliances the supplied N.G.
regulator must be fitted. For L.P.G appliances (Propane
or Universal LP) the test point fitting supplied must be
fitted.
NOTE: The inlet of the regulator or test point fitting should
be fitted to the consumer piping first. The arrow on the
regulator or test point fitting indicates the direction of gas
flow. Then connect the hose to the outlet of the regulator or
test point fitting using the swivel connection on the hose and
fibre washer supplied.
Ensure the regulator or test point fitting is in a
position that is accessible with the appliance
installed and which will allow the appliance to
be withdrawn without disconnecting the hose.
Check all joints and ensure that connections are sound.


Gas flow
to appliance
Internal flange
N.G. Regulator
(P/No. 294-001-031)
Important: flat fibre washer
must be installed
(P/No. 115-009-011)
WMAN_541_Jun10.indd 20 4/6/10 10:18:33 AM