USER MANUAL FOR MODELS: iGen2200 iGen2500 Digital Inverter Generator Digital Inverter Generator 1800 Running Watts | 2200 Peak Watts 2200 Running Watts | 2500 Peak Watts
California Proposition 65 Warning California Proposition 65 Warning Certain components in this product and its related accessories contain chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling. The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects or other reproductive harm.
FOR YOUR RECORDS: Date of Purchase: Inverter Model Number: Purchased from Store/Dealer: Inverter Serial Number: IMPORTANT: KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE. PRODUCT REGISTRATION To ensure trouble-free warranty coverage, it is important you register your Westinghouse inverter. You can register your generator by either: 1. Filling in the product registration form below and mailing to: Product Registration MWE Investments LLC 777 Manor Park Drive Columbus, Ohio 43228 2.
TABLE OF CONTENTS IGEN TECHNICAL SPECIFICATIONS. . . . . . . . . . . . . . 2 PRODUCT REGISTRATION. . . . . . . . . . . . . . . . . . . . . . 3 For Your Records: . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Product Registration . . . . . . . . . . . . . . . . . . . . . . . . 3 Product Registration Form . . . . . . . . . . . . . . . . . . . . 3 SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Safety Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY SAFETY DEFINITIONS The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Be certain that the meanings of these alerts are known to all who work on or near the equipment. SAFETY SYMBOL DEFINITIONS This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.
SAFETY GENERAL SAFETY RULES DANGER Never use the inverter in a location that is wet or damp. Never expose the inverter to rain, snow, water spray or standing water while in use. Protect the inverter from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Never operate the inverter in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the inverter outside and away from windows, doors and vents.
SAFETY SAFETY LABELS AND DECALS IGEN2200 AND IGEN2500 1 2 3 4 5 1 2 5 3 4 UNPACKING CAUTION Always have assistance when lifting the inverter. The inverter is heavy; lifting it could cause bodily harm. Tools required – box cutter or similar device. 1. Carefully cut the packing tape on top of the carton. 2. Remove socket wrench, oil and funnel and save for later. 3. Carefully cut two sides of the carton to remove the inverter.
FEATURES BASIC INVERTER FEATURES IGEN2200 & IGEN2500 1 3 2 5 4 9 8 6 7 1 Fuel Cap and Vent (vent: iGen2200 only): Open the vent to run the engine and close the vent when the engine is off. 2 Control Panel: Contains the reset breaker, outlets and warning lights. 3 Spark Plug Access Cover: Remove the cover to service the spark plug. 4 Recoil Handle: Pull to start the engine. 5 Engine Control Switch: Sets the choke, turns the fuel on and off.
FEATURES CONTROL PANEL FEATURES IGEN2200 1 120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): The outlet is capable of carrying a maximum of 20 amps. 2.1 amps. 8 7 6 2 USB Duplex: 5V DC that come in 1 amps and 3 Reset Breaker: If the inverter is overloaded, the reset breaker will trip. The engine will continue to run, but there will be no output from the inverter. Unplug the devices and reduce the load. Push in the reset breaker to reset it.
FEATURES iGen2500 LED Data Display 1 2 4 6 5 3 1 LOW OIL INDICATOR Description: Lights up red when unit is low or out of oil. Engine will not run when indicator is lit. Recommended Action: When this light appears confirm engine is off, let the unit cool down, then add oil. Make sure to periodically check oil levels while filling to prevent overfilling.
OPERATION BEFORE STARTING THE INVERTER BEFORE STARTING THE INVERTER, REVIEW SAFETY SECTION STARTING ON PAGE 5. Location Selection – Before starting the inverter, avoid exhaust and location hazards by verifying: • You have selected a location to operate the inverter that is outdoors and well ventilated. • You have selected a location with a level and solid surface on which to place the inverter. • You have selected a location that is at least 6 feet (1.
OPERATION POWERCORD Using Extension Cords Westinghouse Portable Power assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable.
OPERATION INITIAL OIL FILL BEFORE ADDING ENGINE OIL, REVIEW SAFETY SECTION STARTING ON PAGE 5. 3. Using the supplied funnel and oil, pour the entire bottle of oil into the engine (see Figure 3). NOTICE Engine oil must be added when the inverter is on a flat, level surface, or an inaccurate reading may result. Do not overfill. If the engine is overfilled with oil, it can cause serious engine damage. 1.
OPERATION ADDING/CHECKING ENGINE FLUIDS AND FUEL BEFORE ADDING/CHECKING ENGINE FLUIDS AND FUEL, REVIEW SAFETY SECTION STARTING ON PAGE 5. ADDING GASOLINE TO THE FUEL TANK WARNING Never refuel the inverter while the engine is running. DANGER Filling the fuel tank with gasoline while the inverter is running can cause gasoline to leak and come in contact with hot surfaces that can ignite the gasoline.
OPERATION STARTING THE INVERTER BEFORE STARTING THE INVERTER, REVIEW SAFETY SECTION STARTING ON PAGE 5. 3. Turn the engine/fuel control switch to the CHOKE position (see Figure 7). OFF RUN For proper starting and operation of the inverter, make sure you review the inverter features and their descriptions starting on page 8. CHOKE Before attempting to start the inverter, verify the following: • The engine is filled with engine oil (see Figure 4: Engine Oil Correct Level on page 13).
OPERATION STOPPING THE INVERTER Normal Operation During normal operation, use the following steps to stop your inverter: 1. Remove any connected loads from the control panel receptacles. 2. Allow the inverter to run at “no load” to reduce and stabilize engine and alternator temperatures. 3. Move the engine control switch to the OFF position (see Figure 10) .
MAINTENANCE BEFORE PERFORMING MAINTENANCE ON THE INVERTER, REVIEW THE SAFETY SECTION STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES. WARNING CAUTION Avoid accidentally starting the inverter during maintenance by removing the spark plug boot from the spark plug. For electric start inverters, also disconnect the battery cables from the battery (disconnect the black negative (-) cable first) and place the cables away from the battery posts to avoid arcing.
MAINTENANCE ENGINE OIL MAINTENANCE Engine Oil Specification 1. Only use the engine oil specified in Figure 12. 2. Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil. NOTICE Engine oil must always be checked and added when the inverter is on a flat, level surface, or an inaccurate reading may result, causing serious engine damage. ADDING ENGINE OIL 1. Always operate or maintain the inverter on a flat surface. 2.
MAINTENANCE CHANGING ENGINE OIL 1. Stop the engine. 2. Let engine sit and cool for several minutes (allow crankcase pressure to equalize). 3. Remove the engine service panel to gain access to the oil fill/drain plug. 4. Place oil pan (or suitable container) under the oil fill/ drain plug (see Figure 13). 7. Allow oil to completely drain. 8. Fill crankcase with oil following the steps outlined in Adding Engine Oil on page 18. 9. Dispose of used engine oil properly.
MAINTENANCE 5. Wash the foam air filter element by submerging the element in a solution of household detergent soap and warm water. Slowly squeeze the foam to thoroughly clean. NOTICE Ho in Dr a el t Bo Floa crew in S ra wl D Fu 6. Rinse in clean water by submerging the air filter element in fresh water and applying a slow squeezing action (see Figure 16). se NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action.
MAINTENANCE SPARK PLUG MAINTENANCE The spark plug must be checked and cleaned after every 100 hours of use or 6 months and must be replaced after 300 hours of use or every year. 1. Stop the inverter and let it cool for several minutes if running. 2. Move the inverter to a flat, level surface. 3. Slide the spark plug access cover off the housing (see Figure 19). 7. Place a clean rag over the opening created by the removal of the spark plug to make sure no dirt can get into the combustion chamber. 8.
MAINTENANCE CLEANING THE SPARK ARRESTOR Check and clean the spark arrestor after every 100 hours of use or 6 months. CHECKING AND ADJUSTING VALVE LASH CAUTION 1. Stop the inverter and let it cool for several minutes if running. 2. Move the inverter to a flat, level surface. 3. Remove the screws holding the muffler cover in place (see Figure 21). Checking and adjusting valve lash must be done when the engine is cold. 1. Remove the rocker arm cover and carefully remove the gasket.
MAINTENANCE CLEANING THE INVERTER It is important to inspect and clean the inverter before every use. Clean All Engine Air Inlet and Outlet Ports – Make sure all engine air inlet and outlet ports are clean of any dirt and debris to ensure the engine does not run hot.
TROUBLESHOOTING WARNING Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner’s manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death. PROBLEM Engine is running, but no electrical output. Engine will not start or remain running while trying to start.
iGen2200 EXPLODED VIEW No Part Description Quantity 1 100509 Discharge Grate 1 2 100514 J Clip 10 3 130523 DC Regulator 1 4 120506 Inverter Module 1 5 170507 Starter Grip 1 7 130521 Control Panel 1 15 150513 Fuel Cap 1 8 100503 Enclosure Side 1 16 100505 Enclosure Side 1 9 100507 Shoulder Bolt 6 17 170522 Side Panel 1 10 100535 Inspection Cover 1 18 170505 Grip Cover 1 11 100520 Rubber Foot 4 19 170508 Fuel Valve 1 12 150515 Fuel Tank 1 20
iGen2200 ENGINE VIEW No Part Description Quantity 1 180558 Dip Stick 1 2 180532 Spark Plug 1 3 140521 Spacer 1 4 140520 Gasket 1 5 180577 Washer 1 6 140522 Stepper Motor 1 7 140523 Gasket 1 8 160503 Air Filter 1 9 110507 Muffler Assy 1 10 180525 Ignition Coil 1 11 110506 Gasket 1 12 140524 Carburetor Assy 1 26 | Westinghouse Portable Power
iGen2500 EXPLODED VIEW No Part Description Quantity 1 100509 Discharge Grate 1 2 100514 J Clip 10 3 130500 DC Regulator 1 4 120500 Inverter Module 1 13 150504 Splash Guard 1 5 170507 Starter Grip 1 14 150509 Fuel Fill Marker 1 6 100519 Intake Grate 1 15 150503 Fuel Cap 1 7 130515 Control Panel 1 16 100505 Enclosure Side 1 7A 130516 Control Panel 1 17 170505 Grip Cover 1 8 100503 Enclosure Side 1 18 170508 Fuel Valve 1 9 100507 Shoulder Bolt
iGen2500 ENGINE VIEW No Part Description Quantity 1 180558 Dip Stick 1 2 180532 Spark Plug 1 3 140521 Spacer 1 4 140520 Gasket 1 5 140511 Carburetor Assy 1 6 140522 Stepper Motor 1 7 140523 Gasket 1 8 160503 Air Filter 1 9 110505 Muffler Assy 1 10 180525 Ignition Coil 1 11 110506 Gasket 1 28 | Westinghouse Portable Power
Spark plug Main winding Control power winding Generator R/W Ignition Coil Br Ignition Bu R W W W Oil Sensor Bu Bl Engine R Bu O Stepper motor R DC Winding Bl Y Bl Inverter Y Bu Bu Bl R Bu Bl W 16AWG Bu 16AWG W R Bu O Bl Y/G 14AWG Gr Bl Br W W W R Y/G Y/G Bl W W Bl R iGEN 2000 iGEN 2500电路图 Idle switch Running lights Fault indicator Reset USB Bl O 黑色 橙色 Oil Indicator Westinghouse Portable Power | 29 用 pdfFactory Pro 测试版本创建的PDF文档 www.pdffactory.
Spark plug Main winding R/W Ignition Coil Br Ignition Bu R W W W Y Control power winding Generator Oil Sensor Bu Bl Engine R Bu O Stepper motor R DC Winding Bl 30 | Westinghouse Portable Power 用 pdfFactory Pro 测试版本创建的PDF文档 www.pdffactory.
Maintenance Notes Westinghouse Portable Power | 31
Version 7.12.