iGen-Manual

14 | Westinghouse Portable Power
iGen2000, iGen2500 & iPro2500
1. Loosen the screw and remove the engine oil ll/
drain plug service panel to access the oil ll/drain
plug (see Figure 3)
Figure 3: Engine Service Panel
2. Clean the area around the oil ll/drain plug and
remove plug (See Figure 4).
Figure 4: Oil Fill/Drain Plug
3. Using the supplied funnel and oil, pour the entire
bottle of oil into the engine (see Figure 4).
Figure 5: Oil Funnel
4. Do not overll, if oil level is too high, oil will drain
out through the ll plug. See correct oil level in
Figure 2.
INITIAL OIL FILL
BEFORE ADDING ENGINE OIL, REVIEW
SAFETY SECTION STARTING ON PAGE 5.
NOTICE
Engine oil must be added when the inverter is on a
at, level surface, or an inaccurate reading may result.
Do not overll. If the engine is overlled with oil, it can
cause serious engine damage.
iGen1200
1. Loosen the screw and remove the engine service
panel to access the oil ll/drain plug (see Figure 1).
Figure 1: iGen1200 Engine Service Panel
2. Clean area around oil ll/drain plug and remove
plug.
3. Using the supplied funnel and oil, pour the entire
bottle of oil into the engine. See correct oil level in
Figure 2 below.
Figure 2: Engine Oil Correct Level
4. Do not overll, if oil level is too high, oil will drain
out through the ll plug.
OPERATION