DRAINING THE FLOAT BOWL
1. Remove the Engine Service Panel to access the
carburetor (see Figure 13 on page 17).
2. Locate the clear plastic hose from the oat that is
extending towards the bottom of the inverter, pull those
hose outside the body and place a suitable container
under it to catch the drained fuel (see Figure 16).
Figure 16: Fuel Drain Hose
3. Loosen the oat bowl drain screw until fuel is seen
draining from the oat bowl (see Figure 17).
Figure 17: Loosen Float Bowl Screw
4. Allow fuel to drain into the container, and then tighten the
oat bowl drain screw.
NOTICE
Never dispose of fuel by dumping fuel into a sewer, on the ground,
or into groundwater or waterways. Always be environmentally
responsible. Follow the guidelines of the EPA or other
governmental agencies for proper disposal of hazardous materials.
Consult local authorities or reclamation facility.
5. Install the engine service panel.
SPARK PLUG MAINTENANCE
The spark plug must be checked and cleaned after every
100 hours of use or 6 months and must be replaced after
300 hours of use or every year.
1. Stop the inverter and let it cool for several minutes if
running.
2. Move the inverter to a at, level surface.
3. Remove the Engine Service Panel to gain access to the
spark plug (see Figure 13 on page 17).
4. Remove the spark plug cover by rmly pulling the
metal spark plug boot handle directly away from the
engine (see Figure 18).
Figure 18: Pull o Spark Plug Cover
NOTICE
Never apply any side load or move the spark plug
laterally when removing the spark plug. Applying a side
load or moving the spark plug laterally may crack and
damage the spark plug boot.
5. Clean area around the spark plug.
6. Using the spark plug socket wrench provided, remove
the spark plug from the cylinder head (see Figure 19).
Figure 19: Remove Spark Plug
MAINTENANCE
fuel pan