User Manual

8 | Westinghouse Portable Power
120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): The
outlet is capable of carrying a maximum of 20 amps.
120-Volt 30 Amp TT-30 Outlet: Travel Trailer outlet
can supply a maximum of 30 amps and 120 volts.
20-Amp Circuit Breakers: Each circuit breaker limits
the current that can be delivered through the 120-volt
duplex outlets to 20amps.
30-Amp Circuit Breakers: Each circuit breaker limits
the current that can be delivered through the 120-volt
TT-30 outlets to 30amps.
USB Duplex: 5V DC USB outlets that come with 1 and
2.1 amp rating.
Reset Breaker: If the inverter is overloaded, the reset
breaker will trip. The engine will continue to run, but
there will be no output from the inverter. Unplug the
devices and reduce the load. Push in the reset breaker
to reset it.
Eciency Mode Switch: When turned to the ON
position, the engine will sense the load needed and run
at a slower RPM to save fuel.
Ground Terminal: The ground terminal is used to
externally ground the inverter.
LED Data Center: Displays remaining run time (F),
power output in kW (P), fuel level in liters (L) and voltage
(V).
Output Ready LED: Indicates the inverter is ready to
be used.
Overload LED: Indicates that the inverter is overloaded.
Low Oil LED: Indicates low oil level.
Battery Charging Port: Used to charge battery when
unit is o.
Fuel Control Switch: Allows fuel to ow to the engine.
Start Indicator: Indicates that power is on, light will
remain lit the whole time the unit is on.
Push Button Automated Start: Push once to
automatically start the engine. Push again to stop the
engine.
Battery Switch: Turns battery on and o. Must be on
before electric start.
Main Breaker: The main circuit breaker controls total
output of all outlets to protect the generator.
FEATURES
CONTROL PANEL FEATURES iGen4500
1
2
3
4
5
6
7
8
9
14
15
16
17
18
14
15
1
2
3 4
6
8
9
10 11 12
13
7
5
16
17
18
% FUEL
REMAINING
% POWER
OUTPUT
Remaining Run Time:
Displays time remaining
with current fuel level and
power output. Does not
display lifetime hours.
Power Output:
Displays electrical power
output to receptacles in
kilowatts.
Fuel level:
Displays current fuel
level in liters.
Voltage:
Displays current voltage
output of generator.
AUTOMATIC ROTATING DATA NUMBER DISPLAY
11
12
13
10