Full Product Manual

English | 11
ASSEMBLY
CARTON CONTENTS
Weight hazard. Always have assistance when lifting the
generator.
1. Carefully open the carton.
2. Remove and save the instruction manual, oil bottle, oil
funnel, spark plug socket wrench, and battery charger.
3. Remove and discard the packing tray.
4. Unfold the top of the plastic bag enclosing the generator.
5. Carefully cut the vertical corners of the carton to access
the generator.
6. Recycle or dispose of the packaging materials properly.
CARTON CONTENTS
User manual
Quick Start Guide
Remote start key fob (attached to recoil starter)
Bottle of SAE 10W-30 Oil
Battery charger
Spark plug wrench
Oil Funnel
Screwdriver
If any parts are missing, contact our service team at
service@wpowereq.com or call 1-855-944-3571.
INITIAL OIL FILL
NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT
OIL. Do not attempt to crank or start engine before it has
been properly serviced with recommended oil. Failure to
add engine oil before starting will result in serious engine
damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types
can cause severe engine damage that is not covered
under warranty.
The included, recommended oil type for typical use is
10W-30 engine oil. If running the generator in extreme
temperatures, refer to the following chart.
1. On a level surface, remove the oil access cover and oil
dipstick.
2. Using the supplied funnel and oil, add oil into the engine.
Note: As residual oil from the factory may remain in the
engine, add the oil incrementally near the end of the
bottle to prevent overlling the engine. See Engine
Oil Level Check in the Maintenance section.
3. Replace the oil dipstick and hand-tighten.
4. Replace the oil access cover.
FUEL
Fire and explosion hazard. Never use a gasoline
container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
Fire and explosion hazard. Do not overll fuel tank. Fill
only to the red ll ring located in the in-tank fuel screen
lter. Overlling may cause fuel to spill onto engine
causing a re or explosion hazard.
Fire and explosion hazard. Never refuel the generator
while the engine is running. Always turn the engine off
and allow the generator to cool for two minutes before
refueling.
NOTICE
Do not use E15 or E85 fuel in this
product. Engine or equipment
damage caused by stale fuel or
the use of unapproved fuels (such
as E15 or E85 ethanol blends) is
not covered by warranty. Only use
unleaded gasoline containing up to
10% ethanol.