b. Remote Start: Push and hold the ON button on the
remote start key fob for one second.
c. Push-Button Start: Push and hold the engine start
button for two seconds.
STOPPING THE ENGINE
1. Turn off and unplug all connected electrical loads.
Never start or stop the generator with electrical devices
connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures.
3. Push and hold the ON/OFF button for one second or
push OFF on the remote start key fob for one second.
4. Push the battery switch to the OFF position.
Note: If the engine will not be used for two weeks or longer,
refer to the Storage section for correct engine and
fuel storage procedures.
PARALLEL OPERATION
Parallel operation gives you the ability to link another
compatible Westinghouse inverter generator for combined
running and peak power output.
DANGER
Fire and electrocution hazard.
Never connect or disconnect the parallel cable leads
when a generator is running. Failure to follow this rule
may lead to serious personal injury or death.
WARNING
Correct connection of the cables
is very important when the generators are used with
a transfer switch to supply power to a building. To
avoid serious personal injury or damage to electrical
devices, including the generators, do not try to power
an electrical system in a building without using an ap-
proved transfer switch.
NOTICE
Connecting to a generator that is
not compatible can cause a low voltage output that
may damage tools and appliances powered by the
generator.
A Westinghouse 507PC (50-amp) or 304PC (30-amp)
parallel cord (purchased separately) is required for parallel
operation. This cord can be purchased from an authorized
Westinghouse Generator dealer.
NOTE: Compatible Westinghouse generators without
parallel ports can be operated in parallel with the recepta-
cle-mounted parallel cable, Part# 507PC.
Refer to the user manual included with your parallel cord
or receptacle-mounted parallel cable for installation and
operation instructions.
ECO MODE
NOTICE
Always start the generator with ECO MODE OFF. Allow
the engine speed to stabilize and the OUTPUT READY
LED to illuminate before switching ECO MODE ON.
Note: Do not use ECO MODE when in parallel operation
with another Westinghouse generator.
ECO MODE minimizes fuel consumption and noise by
adjusting the engine RPM to the minimum required for the
current load.
Turn ECO MODE ON when powering small appliances
with continuous loads such as a computer or electric light.
Turn ECO MODE OFF when powering large surge loads
such as an air conditioner or electric pump.
To turn on ECO MODE, verify that the OUTPUT READY
LED is illuminated green, then push the switch to the ON
position. If no load is present, the generator RPM will drop
to idle speed. The generator will detect loads as they are
applied and increase engine RPM.
To run the generator at maximum power and RPM, push
the ECO MODE switch to the OFF position.
AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if
there is a short circuit or a signicant overload of the
generator at each receptacle. The main circuit breaker
will automatically switch OFF if the combined load of the
receptacles exceeds 31 Amps.
OPERATION