Full Product Manual

English | 7
SAFETY
CO SENSOR
The CO Sensor monitors for the accumulation of
poisonous carbon monoxide gas around the generator
when the engine is running. If increasing levels of CO gas
are detected, the CO Sensor automatically shuts down the
engine.
The CO Sensor will also detect the accumulation of carbon
monoxide from other fuel burning sources used in the area
of operation. For example, if the exhaust of fuel burning
tools is pointed at a CO Sensor-equipped generator, a
shut-off may be initiated due to rising CO levels. This is not
an error. Hazardous carbon monoxide has been detected.
Move and redirect any additional fuel burning sources
to dissipate carbon monoxide away from personnel and
occupied buildings.
Note: Remote start-equipped generators must be restarted
with the START/STOP button on the control panel
after an automatic shut-down occurs.
Generators are intended to be used outdoors, far from
occupied buildings and the exhaust pointed away from
personnel and buildings. If misused and operated in a
location that results in the accumulation of CO, like in
a partially enclosed area, the CO Sensor shuts off the
engine, noties the user with a RED indicator light, and
directs the user to read the Action Label for steps to take.
The CO Sensor DOES NOT replace carbon monoxide
alarms. Install battery-powered carbon monoxide alarm(s)
in your home.
Automatic shutoff accompanied with a ashing RED
light in the CO Sensor portion of the control panel is an
indication that the generator was improperly located. If
you start to feel sick, dizzy, weak, or carbon monoxide
detectors in your home indicate an alarm, get to fresh
air immediately. Call emergency services. You may have
carbon monoxide poisoning.
ACTION LABEL
CONTROL PANEL CO AUTO-SHUTOFF
CO SENSOR INDICATOR LIGHTS
Color Description
RED
Carbon monoxide accumulated around
the generator. After shut-off, the RED
indicator light in the CO Sensor area of
the control panel will ash to provide
notication that the generator was shut-off
due to an accumulating CO hazard. The
RED light will ash for at least ve minutes
after a CO shut-off.
Move the generator to an open, outdoor
area far away from occupied spaces with
exhaust pointed away. Once relocated to a
safe area, the generator can be restarted.
Introduce fresh air and ventilate the area
where the generator had shut down.
YELLOW
A CO sensor system fault occurred. When
a system fault occurs, the generator is
automatically shut down and the YELLOW
indicator light in the CO auto-shutoff area
of the control panel will ash to provide
notication that the fault has occurred.
The YELLOW light will ash for at least
ve minutes after a fault. The generator
can be re-started, but may continue to
shutoff. A CO sensor fault can only be
diagnosed and repaired by an authorized
Westinghouse service center.