Full Product Manual

Westinghouse Portable Power | 19
Oil Fill/Drain Plug iGen2000, iGen2500 & iPro2500
7. Check oil level: When checking the engine oil,
remove the oil ll/ drain plug.
The oil level is acceptable if oil is visible at the
bottom of the threads of the oil ll plug.
If oil level is low, add to the correct level using
the supplied oil ll bottle. Do not overll the oil
crankcase.
NOTICE
Engine oil must always be checked and added when
the inverter is on a at, level surface, or an inaccurate
reading may result, causing serious engine damage.
ADDING ENGINE OIL
8. Always operate or maintain the inverter on a at
surface.
9. Stop engine if running.
10. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
11. Remove the engine service panel to gain access to
the oil ll/drain plug.
12. Thoroughly clean around the oil ll/drain plug.
13. Remove the oil ll/drain plug.
14. Select the proper engine oil as specied in Figure
14.
15. Using the supplied oil funnel, slowly add engine oil
to the engine. Stop frequently to check the oil level
and avoid overlling.
ENGINE OIL MAINTENANCE
Engine Oil Specication
1. Only use the engine oil specied in Figure 14.
2. Only use 4-stroke/cycle engine oil. NEVER USE
2-STROKE/CYCLE OIL. Synthetic oil is an
acceptable substitute for conventional oil.
Figure 14: Recommended Oil
CHECKING ENGINE OIL
NOTICE
Always maintain proper engine oil level. Failure to
maintain proper engine oil level could result in severe
damage to the engine and/or shorten the life of the
engine.
Always use the specied engine oil. Failure to use the
specied engine oil can cause accelerated wear and/
or shorten the life of the engine.
Engine oil level should be checked before every use.
1. Always operate or maintain the inverter on a at
surface.
2. Stop engine if running.
3. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
4. Remove the engine service panel to access the oil
ll/drain plug.
5. With a damp rag, clean around the oil ll/drain plug.
6. Remove the oil ll/drain plug.
Oil Fill/Drain Plug iGen1200
MAINTENANCE