Specifications
Section 6: Commands
6-11
3. At this time, you may select to jump to any of the available fields by typing the number and
pressing Enter. For the default 1, the screen displays:
1. NAME (24): ?
4. Type a name with a maximum of 24 characters. Descriptive names such as FRONT LOBBY
or DELIVERY ENTRANCE are advised. Press Enter.
5. The screen displays:
2. KEY TRACE REPORT (0-32): 1?
Prompt 2 is the first of several fields which allow you to assign a report number to various
door activities. If any of the log events do not require a report, enter 0. All log events in the
DOOR command prompts are factory set to report 1.
The key trace function may be enabled for individual users with the KEY command or for a
number of users with the GROUP command. Field 2 assigns a report to key trace actions.
3. ACCESS GRANTED REPORT (0-32): 1?
4. ACCESS DENIED REPORT (0-32): 1?
Access granted or denied reports are enabled for the specified door by entering a number
in fields 3 and 4. A log message is generated each time a command key is presented to a
proximity reader or a PIN is entered on a VIP2 associated with the door. (Door functions can
be disabled with the SHUNT command. See Section 6.3.18.
5. DOOR OPEN TOO LONG REPORT (0-32): 1?
This report is generated when the door open time period specified in field 13 below is
exceeded.
6. DOOR FORCED OPEN REPORT (0-32): 1?
A door is considered forced open when no access or exit granted is pending. A request-to-
exit (REX) switch can be used to signal a valid door opening; see field 15 below.
7. COAX FAIL REPORT (0-32): 1?
A failure to the coaxial cable associated with the door, sensor port, will generate this report.
A cable short is an example of a coaxial failure.
6. Press Enter after selecting each report number for fields 2 though 7. The screen displays:
8. SELECT READER TYPE
8A. SENSOR ENABLE (Y/N): Y?
7. Set the SENSOR ENABLE field to Y if an analog proximity sensor will be used on this door
(sensor port). If N is entered field 8B is skipped. For a Y response, the screen displays:
8B. SENSOR FAIL REPORT (0-32): 1?