Specifications

Alto 818 Installation and Operation
6-12 P/N 66109074001 Rev. D
8. Select a report, 032, for a failure of the analog sensor. Press Enter. The screen displays:
8C. SNET READER TYPE (NONE/DKR/SCR): DKR?
9. If an S-Net device, other than a VIP2, is to be used for this door, enter DKR for a digital reader
or SCR for an AT&T Smart Card reader. For no S-Net device, enter NONE. Press Enter.
For entries other that NONE, the screen displays:
8D. SNET READER FAIL REPORT (0-32): 1?
10. Designate a report to be associated with a failure of the above specified S-Net device. Type
a number, 032 and press Enter. If DKR was input for field 8C, the screen displays:
8E. DIGITAL KEY READER RANGE (0-255): 254?
11. See the appropriate digital reader manual for details on the read range. Type the desired
value and press Enter. The screen displays:
9. MSM ENABLE (Y/N): Y?
12. Enter Y if an MSM is connected to this door, sensor port; otherwise type N. Press Enter. For
a Y entry, the screen displays:
9A. MSM FAIL REPORT (0-32): 1?
13. Select a report number to be associated with an MSM failure, 0 for no report, and press Enter.
The screen displays:
10. SENSOR TYPE (NORMAL/OPEN/CLOSED/STATION): NORMAL?
14. The sensor type refers to any proximity sensor, analog or digital, or VIP2. The sensor type
is only valid when building modes are utilized. Select a type and press Enter. The screen
displays:
11. ANTI-PASSBACK (NONE/ENTRY/EXIT): ENTRY?
15. If anti-passback control is to be used, each door must be designated as an entry or an exit.
When enabled, a valid entry sets the user's location as IN. A valid exit sets the user's location
as out. An attempt to enter while a user's location is set to in constitutes a passback violation.
Similarly, an exit request while out is a violation. Make a selection and press Enter. When
ENTRY or EXIT is entered for field 11, the screen, displays:
11A. TYPE (HARD/SOFT): HARD?
16. Hard anti-passback will not grant access and will generate as anti-passback log message.
Soft anti-passback will allow access while generating an anti-passback log message. Type
H for hard or S for soft. Press Enter. The screen displays:
* Prompts 8C through 8E are valid only on an SE 818SC.