Operating Instructions

38
INSTALLATION
INSTALLATION OF ANTI-TILT BRACKETS AND HOOK
• Theanti-tiltbracketsmustbesecuredtothefloorat
rearofcavitywithanappropriatefasteneraccording
todimensionsindiagram
• Thehookistobesecuredtothebackwallinthe
locationshownabovewithanappropriatefastener
capableofwithstandinga10kgload
• Connectservicestotheappliancepriortoplacing
intocavity
• Tolocateappliance,slideintocavityandensuring
therearleftandrightfootofappliancearecaptured
bytheanti-tiltbrackets
• Beforetheapplianceisfullypushedintoposition,
placethechainattachedtotherearofappliance
ontothewallhook
Appliance
Wall
Chaininstalled
INSTALLATION OF THE APPLIANCE
Hook
Measurements are to be adjusted to account for the thickness of any skirting
board or tiles coming between the back of the appliance and the wall.
C
L
425
194
376
Holelocationfor
hookinstallation
425
840
376
Measurementsaretobeadjustedtoaccountfor
thethicknessofanyskirtingboardortilescoming
betweenthebackoftheapplianceandthewall
194