Operating Instructions

44
ELECTRICAL & GAS CONNECTION LOCATIONS
INSTALLING THE GAS COOKER
GAS TYPE NATURAL GAS UNIVERSAL LPG
Supplypressureatinletto
applianceregulator(iffitted)
1.13(kPa)
Minimum
2.75*
(kPa)
Operatingpressureat
appliancetestpoint
1.00(kPa) 2.75(kPa)
*Iftheregulatorisplacedupstreamofthecookerinlet,as
isnormalforcookersoperatingonLPG,thenthesupply
pressureandoperatingpressurearethesame.
Thefollowingtableshowstheinjectorsizesforeach
burner.
INJECTOR ORIFICE NATURAL GAS UNIVERSAL LPG
Lowheatburner 1.00mm 0.55mm
Mediumheatburner 1.35mm 0.70mm
Highheatburner 1.60mm 0.90mm
Intenseheatwokburner 1.75mm 1.00mm
GAS CONNECTION
Readthesepointsbeforeconnectingtothegassupply:
• Theapplianceispresetfornaturalgasuse,ifLPGis
tobeusedseeConversiontoLPGsection.
• Gasinstallationmustbemadeinaccordancewith
AS5601,thelocalgasfittingregulations,municipal
codesandotherstatutoryregulations.
• Thegasconnectionpointisa½”BSPexternalthread
locatedattherearoftheapplianceasshown.
• Aregulatorissuppliedwhichmustbefittedtothe
appliance.Ensurethatwhenfittedthepressuretest
pointofregulatorisaccessible.
• Theregulatoristobefittedtotheappliance
connectionpoint,thenfithardpipingfromthe
regulatortotheconsumerhardpiping.Ensurethe
installationallowsthewithdrawaloftheappliance.
Donotuseaflexiblehosetoconnecttheapplianceto
thegassupply.
CHECKING PIPING SIZE
Toworkoutasuitablepipesizeforconnectionuse:
Theinformationinthistable
GAS TYPE NATURAL GAS UNIVERSAL LPG
WFE912&WFE914 49.6MJ/h 40.9MJ/h
WFE916 58.6MJ/h 47.4MJ/h
Informationaboutthelengthofrun,numberofelbows,
teesandbends,theavailableservicepressureandthe
supplyrequirements.
NOTE: AS/NZS5601.1 will help you with this matter.
INSTALLATION
MODELS WFE912, WFE914, WFE916 AND WFE946
GAS PRESSURES
Thefollowingtableshowsthesupplyandoperating
pressuresforvariousgases.
168
95
Electricalconnectioncable
806
411
Gasconnectionpointtoregulator
Models:WFE912,WFE914,WFE916
Electricalcable
entrypoint
Models:
WFE912,WFE914,
WFE916,WFE946