Operating Instructions

45
INSTALLATION
LPG CONVERSION
MODELS WFE912, WFE914 & WFE916
ThisapplianceissuppliedsetuptoforNaturalGas
usage.Aconversionkitisincludedwiththeproduct
forUniversalLPGusage.Theconversionkitcontains6
injectorsand1LPGsticker.
Pleasefollowtheprocedurebelowifaconversiontosuit
UNIVERSALLPGisrequired.
1. Removethehotplatetrivets,burnercapsandburner
crownstoaccessthehotplateinjectors.Replacethe
factoryfittedinjectorswiththeappropriateinjectors,as
supplied.Refertoinjectororificetableforinjectorsizes.
Theinjectorsizeisstampedonthesideoftheinjector.
2. Unscrewthehexnutfromtheregulator.Thehexnut,brass
washerandnyloninsertwilldisengageasanassembly.
3. Unclipthenyloninsertfromthenutassemblyby
rotatingtheinsert1/4turn,andpullingitfree.
4. Turnovertheinsert,andclipbackintoposition.
5. Refitthehexnutassemblytotheregulatorensuringthat
itisfullyscreweddown.Theregulatorisnowsetfor
connectiontoLPG.
6. Turnonthegassupplyandateachnewconnection
checkforleaksusingsoapywater:eachhotplate
valveshouldbeturnedon,oneatatime,andthe
injectorholeblankedoffforseveralseconds.
7. Theoperationoftheregulatorcanbeconfirmedby
connectingamanometertothepressuretestpoint
locatedonthesideoftheregulatorbodyadjacentto
theoutlet.
Withtheapplianceoperatingchecktheoutletpressure
•whenallburnersoftheapplianceareoperating
atmaximum,
•whenthesmallestburneroftheapplianceis
operatingatminimum.
Undertheseconditionstheoutletpressureshouldnot
varyfromthenominaloutletpressureof2.60kPaby
morethan±0.52kPa.
8. Iftheregulatorappearstonotbeperforming
satisfactorilythencheckthefollowingpoints.
•Iftheoutletpressureisconsistentlytoolowthen
theinletpressuremaybetoolowandadjustment
ofanupstreamregulatormaybeneeded,oran
upstreamregulatororvalvewithinsufficientflow
capacitymaybepresentinthegassupplyline.If
thisissuspectedthenitmaybenecessarytorepeat
thecheckswhilstmeasuringboththeinletandoutlet
pressuretodetermineiftheinletpressureisinthe
range2.75–7.00kPa.
•Checkthattheinserthasbeenfittedcorrectly.
•Checkthattheturretscrewisfullyscreweddown.
•Checkthattheregulatorhasbeenfittedtothegas
supplylineinthecorrectorientation,thearrowonthe
baseofthebodyindicatesthedirectionofgasflow.
Oncethesecheckshavebeencompleted,iftheregulatorstill
failstoperforminasatisfactorymanneritshouldbereplaced.
9. Onebyone,turntheknobstominimumandscrew
inthebypassscrew(accessiblewhentheknobis
removed)untilasmallstableflameresults.Turnthe
knobtomaximumandthenbacktominimumtoensure
thatthecorrectminimumflameismaintained.
10.AttachtheLPGstickertothecooker,nearthegas
supplyinlet.CovertheNaturalGaslabelthatis
factoryfitted.
Hexnutassembly,
fullyscreweddown
Insertorientedfor
naturalgasoperation
HexNutassembly,
removedfrom
regulatorand
insertdisassembled
Insertorientedfor
LPGoperation
Flamesizeadjustedtomaximum
Flamesizeadjustedtominimum
Bypassscrew
Controlknobshaft