Full Product Manual

Westinghouse Outdoor Power Equipment, LLC | 15
6. Remove the safety plug or cap from the propane tank
valve and attach the other end of the hose to the LPG/
propane connector on the tank. Hand tighten.
7. Turn the propane tank valve to the fully open position.
Check all connections for leaks by wetting the ttings
with a solution of soap and water. Bubbles which appear
or bubbles which grow indicate that a leak exists. If a
leak exists at a tting, turn the propane tank valve to
the fully closed position and tighten the tting. Open the
propane tank valve and recheck the tting with the soap
and water solution. If the leak continues or if the leak
is not at a tting then DO NOT use the generator and
contact customer service.
IMPORTANT: Keep the propane tank valve in the fully
closed position unless in use.
CONNECT THE BATTERY
WARNING
Explosion hazard. Batteries emit explosive gases while
charging. Keep re and spark away.
A quick-connect battery plug is pre-installed on the battery.
Remove the cable tie securing the plugs then push rmly
to connect them.
Note: The generator is equipped with a battery charging
feature. Once the engine is running, a small charge
will slowly recharge the battery.
ASSEMBLY