Installation Instructions
whl-590 Rev. 003 Rel. 003 Date 3.22.18
13
I. Technical Specications
Model 150 199
Installation Indoor, Wall Hung, Fully Condensing
Minimum / Maximum Input (Btu/Hr) 15,000 / 150,000 19,900 / 199,000
Hot Water Capacity
35
o
F Rise 8.2 GPM 11 GPM
45
o
F Rise 6.4 GPM 8.5 GPM
77
o
F Rise 3.7 GPM 5 GPM
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent
Vent Run 2” (50 feet), 3” (100 feet), Schedule 40 PVC, CPVC, PP
Weight (lbs) 90 100
Orice Size
NG 7.2 mm (0.284”) 8.3 mm (0.327”)
LP 5.5 mm (0.217”) 6.2 mm (0.240”)
Gas Supply
Pressure
NG
3.5” to 14” WC
LP
Manifold
Pressure
Min (3”) NG/LP: 0.006” NG: 0.003” / LP: 0.004” WC
Max (3”) NG/LP: -0.13” NG: -0.19” / LP: -0.20” WC
Power
Supply
Main Supply 120V 60 Hz, 10A
Maximum Power
Consumption
72W (with Pump 100W)
General Operating Conditions
Ambient Temperature Range: 33 – 104
o
F (0.6 – 40
o
C)
Operating Relative Humidity: Up to 90% at 104
o
F (40
o
C)
Shipping and Storage Temperature Range: -4 – 176
o
F (-20 – 80
o
C)
Power Supply and Communication (CN4): 14V DC
Product Approvals and Requirements
EMC: 89/336/EEC
LVD: 73/23/EEC
Ignition System Direct Electronic Ignition / Automatic Flame Sensing
Burner System Single Orice Premixed Fuel Modulation / Ceramic Fiber Burner
Gas Valve System Air Ratio Valve
Minimum Flow Rate 0.5 GPM (zero activation with internal recirculation mode active)
Internal Pipe Material Copper
Dimensions W 17.5” - H 30” - D 15.5” W 19.7” - H 32” - D 16.3”
Heat Exchanger Water Capacity (DHW) 2.3 Gallons 3.5 Gallons
Control Panel / Main Controller P-950CH / NGTH-10CH
Water Pressure Min 12 - Max 150 PSI
DHW Setpoint Temperature Range 100 – 140
o
F (35 – 60
o
C)
Connection
Sizes
Cold Water Inlet /
Hot Water Outlet /
Recirculation Return
3/4” NPT
Gas Inlet 3/4” NPT
Materials
Cabinet Cold Rolled Carbon Steel
Heat Exchanger 316L Stainless Steel
Safety Devices
Optical Flame Sensor, Burner Plate High Limit (392
o
F), Water Temperature High Limit Sensor
(203
o
F), Water Leak Detection, Freeze Protection (Three Stage Operation - Activates at
46
o
F – See Freeze Protection in Installer Menu for Details), Exhaust Temperature High Limit
Sensor (190
o
F), Blocked Flue and Intake Sensor, Condensate Switch, Built-In Low Water Cut-
O Probe
Table 8 - Technical Specications