Use And Care Manual
whl-590 Rev. 003 Rel. 003 Date 3.22.18
55
Figure 59 - A - Selecting a Recirculation Function, B - Entering Day Setting
e. The default day is displayed when the program function is selected. Press the button to remove a day. Turn the dial to select other
days. See Figure 64 A.
f. Press the
gu
button to set the time. See Figure 64 B.
Figure 60 - A - Selecting the Day, Turning the Dial to Other Days, B - Setting the Time
i. Turn the dial button to set the time. See Figure 65 A. Wait for the time to ash twice.
j. Press the button to store the time setting. See Figure 65 B.
NOTE: If a mistake is made when setting the date or time, it can be cleared or restored to the default time. Press the key to select Clr
(to clear the date and time) dEF (to restore the date and time to the factory default).Press the button to clear or restore. Or go to the
Installer Menu, 3: In, to reset the unit to factory settings and start over.
Figure 61 - A - Setting the Time, B - Storing the Time Setting
k. Press the button to store the time setting. Press the button again to leave Recirculation Function.
l. The water heater is now ready to operate in the selected Recirculation Function.
Part 10 - Troubleshooting
A. Error Code
When the water heater encounters an error, the display will ash “Er” followed by a numerical code. The water heater shall enter a soft lockout
condition if the error is such that it can return to normal operation once the condition relieves itself (overheat conditions, NTC open or shorts,
etc.). The water heater shall enter a hard lockout if the condition indicates something more serious (ame, ignition, condensate line, etc.) To
clear a hard lockout Error Code, press the Power button. See Figure 66 B.
The following screen will display when the water heater encounters an error.
Figure 62 - A - Error Screen, B - Resetting an Error Code