Installation Instructions

whl-004 Rev. 000 Rel. 012 Date 3.22.18
5
Improper venting can cause a build-up of carbon monoxide.
Breathing carbon monoxide can result in brain damage or death.
DO NOT operate the water heater unless it is properly vented to
the outside and has an adequate fresh air supply for safe operation.
Inspect the exterior exhaust gas outlet port and fresh air inlet port
on a regular basis to ensure they are functioning properly.
A concentration of carbon monoxide as small as .04% (400 parts
per million) in the air can be fatal. When making high re or low
re adjustments, CO levels must be monitored using a ue gas
analyzer such that a CO level of no more than 150 ppm is exceeded
at any time during operation.
Adjusting the “low re oset” or the “main ow restrictor in small
increments can result in a signicant increase in CO concentration.
To avoid serious injury or death, DO NOT make any adjustments to
the gas valve without monitoring the exhaust gases with a fully
functional and calibrated ue gas analyzer.
This water heater must be installed by a licensed plumber, licensed
gas tter, and/or qualied installer / service technician. Improper
installation and/or operation can cause a potentially hazardous
situation, which, if not avoided, could result in serious injury or
death, and will void the warranty.
The manufacturer cannot anticipate every circumstance that
might involve a potential hazard. Each installation has its own
specialized characteristics, requirements, and possible hazards.
Therefore, all possible incidents are not included in these
warnings. Proper and safe installation, operation, and service are
the responsibility of the qualied installer / service technician.
Proper care of the water heater is the user’s responsibility. Ensure
the user carefully reads and understands the User’s Information
Manual before operating and maintaining the water heater.
Make sure the user knows the location of the gas shut-o valve
and how to operate it. Immediately close the gas shut-o valve if
the water heater is subjected to re, overheating, ood, physical
damage, or any other damaging condition that might aect the
operation of the unit. Have the water heater checked by a qualied
technician before resuming operation.
Do not power up the unit unless the gas and water supply valves
are fully opened. Make sure the fresh air intake port and exhaust
gas port are open and functional.
No one but a qualied installer / service technician should
attempt to install, service, or repair this water heater. There are
no serviceable parts which can be changed by the user / owner.
User / Owner: Contact the original qualied installer / service
technician if the water heater needs repair or maintenance. If the
original technician is unavailable, ask your gas supplier for a list of
qualied service providers.
Keep the area around the water heater clean and free of all
materials that can burn. DO NOT store or place gasoline, oils, spray
paint, or other ammable products near the water heater.
DO NOT use spray paint, hair spray, or any other ammable spray
near the water heater or near the exterior fresh air intake port. DO
NOT place any items in or around the exterior exhaust gas outlet
port and/or fresh air inlet port that could restrict or block the ow
in or out of the vent system.
DO NOT store or place newspapers, laundry, or other combustible
items near the water heater or the exterior exhaust gas outlet and/
or fresh air inlet port.
After installation, all water heater safety devices should be tested.
This water heater is certied for indoor installations only. The water
heater consists of gas ignition system components which must be
protected from water (dripping, spraying, etc.) during operation and
service. Carefully consider installation location and the placement
of critical components (circulators, condensate neutralizers, etc.)
before installing the water heater.
DO NOT allow children to operate this unit. DO NOT use this unit if
it does not appear to be operating correctly. A qualied technician
should service and inspect the water heater annually.
The water heater temperature is factory set to 125
o
F (51.7
o
C). To
avoid scalding, always check the temperature of the hot water
before bathing, showering, washing, etc. DO NOT adjust the water
temperature while the water heater is being used by other persons.
This water heater is equipped with a three prong plug. It should
only be plugged directly into a properly grounded three prong
receptacle. DO NOT remove the ground plug from the plug.
Any claims for damage or shortage in shipment must be led
immediately against the transportation company by the consignee.
This water heater provides a overheat shutdown limit. In the event
the water heater water exceeds the set point of the control limit, the
cuto will trip and the water heater will shut down. Certain local
codes require additional temperature limits. In addition, certain
types of systems may operate at temperatures below the minimum
set point of the limit provided with the water heater. Contact the
manufacturer for additional overheat controls.
NOTE: When inquiring about service or troubleshooting, reference the
model and serial numbers from the water heater rating label.
The owner should inspect the system monthly for damage, water
stains, signs of rust, corrosion, and exhaust vent and air intake
blockage. If inspection of the unit shows signs of damage, the water
heater should be shut o until the problem is repaired by a qualied
technician.
DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN
SUBMERGED IN WATER. Immediately call a qualied installer /
service technician. The water heater MUST BE replaced if it has
been submerged. Attempting to operate a water heater that has
been submerged could create numerous harmful conditions, such
as a potential gas leakage causing a re and/or explosion, or the
release of mold, bacteria, or other harmful particulates into the
air. Operating a previously submerged water heater could result in
property damage, severe personal injury, or death.
NOTE: Water heater damage due to ood or submersion is considered
an Act of God, and IS NOT covered under product warranty.
NOTE: If the water heater is exposed to the following, do not operate.
Immediately call a qualied installer / service technician.
1. Fire
2. Damage
3. Water
Failure to follow this information could result in property damage,
severe personal injury, or death.
DO NOT alter or modify the water heater or water heater controls.
Altering any Westinghouse water heater with parts not manufactured
by Westinghouse WILL INSTANTLY VOID the water heater warranty
and could result in property damage, personal injury, or death.