INSTALLATION
Standard ducting installation
It is recommended that the unit be positioned at a
minimum of 600mm for an electric cooktop and 650mm
for a gas cooktop, and no further from the cooktop than
800mm. The unit becomes less effective as the distance
from the cooking surface to the rangehood increase.
650
GAS
ELECTRIC
600
Fixing point dimensionsWRI514BB
Fixing point dimensions WRI814BB
WARNING!
Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards.
Parts supplied with hood
1 x Ø 150mm air outlet
2 x self tapping screws 3.5 x 12mm
Parts to be purchased
Aluminium tape or cable ties to secure flue pipe
Ducting acce
ssories
Cutting the cabinet
Cut the slot in the cabinet according to the fixing
point dimension.
Fixing the air outlet
underside of
rangehood
top of cooking
surface
if the cooktop
manufacturer
specifies
a greater
clearance
then that
must be used
Use screws to fix the air outlet to the rangehood.
1 x Ø 150-120mm reducer
4
5
4
4
9
2
2
5
4
2
7
7
1
5
0
2
8
2
4
5
7
~
4
7
5
2
6
0
~
2
6
5
Cabinet
12~23
7
9
2
7
4
4
2
7
7
2
5
0
3
1
2
1
5
0
Cabinet
7
6
2
~
7
6
6
2
5
7
~
2
6
3
12~23
Fixing the rangehood
Fix the rangehood to the cabinet from bottom side
untill you hear the ‘click’ sound.
ST 3.5x12