User Manual

43INSTALLING THE FREESTANDING COOKER
INSTALLING THE FREESTANDING COOKER
Gas connection
Read these points before connecting to the gas supply:
The appliance is preset for natural gas use, if LPG is
to be used see Conversion to LPG section.
Gas installation must be made in accordance with AS/
NZS5601.1, the local gas fitting regulations, municipal
codes and other statutory regulations.
The gas connection point is a ½” BSP external thread
located at the rear of the appliance as shown.
The regulator is to be fitted to the manifold inlet at
the rear of the appliance and the connectionis sealed
using a tape or jointing compound suitable for gas
connections. The consumer piping is then connected to
the inlet of the regulator, either
1. directly, or
2. using a hose assembly and in accordance
with Clause 6.10.1.9 of AS 560101 (High level
connection) together with the supplied elbow.
The elbow is fitted to the inlet of the regulator
and oriented to allow the hose to hang
downward. The connection thread between the
regulator and elbow is sealed using a tape or
jointing compound suitable for gas connections.
Models WFE914SB, WFEP915SB AND WFE946SB
168
95
Electrical connection cable
806
411
Gas connection point to regulator
Models: WFE914SB, WFEP915SB
Electrical cable
entry point
Models: WFE914SB,
WFEP915SB,
WFE946SB
Gas pressures
The following table shows the supply and operating
pressures for various gases.
GAS TYPE
NATURAL
GAS
UNIVERSAL
LPG
Supply pressure at inlet
to appliance regulator
(if fitted)
1.13 (kPa)
Minimum
2.75*
(kPa)
Operating pressure at
appliance test point
1.00 (kPa) 2.6 (kPa)
*If the regulator is placed upstream of the cooker inlet, as is normal
for cookers operating on LPG, then the supply pressure and
operating pressure are the same.
The following table shows the injector sizes for
each burner.
INJECTOR ORIFICE
NATURAL
GAS
UNIVERSAL
LPG
Low heat burner 1.00mm 0.55mm
Medium heat burner 1.35mm 0.70mm
High heat burner 1.60mm 0.90mm
Intense heat wok
burner
1.75mm 1.00mm
Checking piping size
To work out a suitable pipe size for connection use the
information in this table.
GAS TYPE NATURAL
GAS
UNIVERSAL
LPG
WFE914 & WFEP915 49.6 MJ/h 40.9 MJ/h
For information and requirements about construction and
capacity of consumer piping refer to AS5601 series of
standards.