User's Manual

Sentinel Installation Manual
7
Tag and POS RAD Operation
Once the Sentinel system has been set up and tuned, the only remaining function is to attach Sentinel
tags to the articles and arming them. This section describes the steps in controlling the tags and other
features to assist in maintain control over the protected area. The Mode Switch selects between arming
and disarming a Sentinel tag as indicated by the left and right indicators. The Magnetic Detacher is used
to unlock the tag for removal from the protected article after disarming.
1. Power Up
The POS RAD is powered by 24vac power same as Field RAD or by any PC USB port (5V 500mA).
There is a switch on POS RAD which is default set as POS RAD Mode switch button.
One press this button each time will switch the POS to next Mode. There are altogether three modes
(see the mode table below.)
User can also configure the POS RAD into dedicated modes, please find reference at Appendix:
RAD’s DIP Switch Configuration.
2. Tag Arming
Set the Mode Switch in the position so the Arm Indicator is lit. Then place the tag on the surface of the
RAD. A single beep will signify the tag has been armed. The tag will also flash approximately once per
second to indicate it is in the armed condition.
Notice: If armed tags without movement over one minute, tag circuit will automatically turn off RF
function to save power, the LED on tag will stop flashing too. But it doesn’t mean tag is off work. Tag
will reactivate itself when movement of tag is detected.
3. Tag Disarming
Set the Mode Switch in the position so that both the Disarm and Arm Indicators are lit. Then place the
tag on the surface of the RAD. A single beep will signify the tag has been disarmed. The tag may now
be opened without self-alarming. In this condition the tag may be removed from the protection zone
without alarming. In this stage the tag will not respond to any commands except the Arm command
from the POS RAD.
Mode Arm Indicator
Blue LED
Disarm Indicator
Red LED
Arm Mode On Off
Disarm Mode Off On
Disalarm Mode On On
Off Work Off Off
Disarm Indicato
r
Arm Indicato
r
Switch
Ma
g
netic Detache
r