Premier Guard Installation Manual
12
Connecting the Pedestal
Before the connecting the transceiver, place it at the location where you intend to install it,
and arrange the cables directly from the PLCU to the transceiver.
1. Remove the base cover of the pedestal to expose the transmitter board (picture below).
Note: Press down the top of base cover towards pedestal and LIFT the half case upward to
release the cover from the pedestal’s locking mechanism.
2. Loosen the screws to remove the cable wires from the connector. Feed the cable through
the slot of the aluminum base mounting plate, and then reconnect the cable wires to the
connector according to wire connection table.
3. Plug the three connectors (Power, Tx Signal and Rx Signal) onto the appropriate sockets
on the transmitter board (see picture below).
4. After completing all connections, firmly mount the pedestal base to the ground. (See
following page.)
5. Re-install the base cover.
From
Transformer
Box
Removing The Base
Use a screwdriver to punch
the cover at the hole. The
cover lock will release, and
then you can take apart the
two halves.
Power Sockets
(3 Pins)
Control Signal
Sockets (3 Pins)
RX Signal
Sockets
(
2 Pins
)
From PLCU
Either of the two
pedestal sockets
Clockwise
– increase sensitivity
prone to false alarms
Counter-Clockwise
– decrease sensitivity
less false alarms
Rx signal pre-process sensitivity
From PLCU