User Manual

Premier Guard Installation Manual
14
Cable and Connector Connections
1 Pedestal and Transformer Box Power Connection
The three pins from the transformer power connecter are connected to the corresponding
pedestal connector sockets. Pin color to each power connecters must be consistent.
Transformer Box Power Terminal Layout
(3 pins)
White Cable (3 wires)
Pin Function Color
Pin 1 0V Blue
Pin 2 Ground Green w/Yellow Stripe
Pin 3 24V Red(Brown)
When connecting the above pedestal power connectors, make sure the pin
order/color of the four power connectors is consistent. Do not transpose the
color order when connecting wires to connectors. Incorrect pin connection
will damage the system!
Pedestal Connector Layout
(3 pins)
White Cable (3 wires)
Pin Function Color
Pin 1 Blue
Pin 2 Green w/Yellow Stripe
Pin 3 Red(Brown)
The Power Terminal
on Transformer Box
24VAC
O UTPUT
0V
GND
24V
Pin 1
Pin 2
Pin 3
Green with yellow stripe
Red (brown)
Blue
Pin 1
Pin 2
Pin 3
To pedestal 1
Wire size is 20 AWG