User Manual

Premier Guard Installation Manual
16
3. Pedestal and PLCU TX Control Signal Connection
PLCU TX Control Signal
Connector Layout
(3 pins)
Black Cable (3 wires)
Pin Function Color
Pin 1 Signal+ Blue
Pin 2 Signal- Brown
Pin 3 Shielding GND
Sockets connection note:
To ensure good contact and proper connection from the pedestal to the PLCU, make sure the
cable sockets are firmly connected and the pins are correctly aligned.
Pedestal TX Control Signal
Connector Layout
(3 pins)
Black Cable (3 wires)
Pin Function Color
Pin 1 Signal+ Blue
Pin 2 Signal- Brown
Pin 3 Shielding GND
1 2
3
Aligning Key
PLCU Socket
2
1
3
Aligning Slot
TX Control Connector
Incorrect pin mapping and loose contact connections
will result in system malfunction!
Insert connector into socket, turn the
screw cap, lock and set.
Procedure
1. Ensure the
aligning key
mates to the
aligning
slot,
2. Insert the TX control connector into the socket
of the PLCU.
3. Turn the screw cap according to the figure on
the left, then lock and set.
Pin 1
Pin 2
Pin 3
Pin 1 Blue
Pin 2 Brown
Pin 3 Shield
To PLCU
To Pedestal
Wire size is 22 AWG, Shielded