User Manual

Premier Guard Installation Manual
29
Noise Condition Display Configuration Table
Value Function Description Detection Purpose
0 Shut down tag or noise window display.
D1 Tag window display for channel one. Detect tag entering vertically.
D2 Tag window display for channel two. Detect tag entering horizontally.
D3 Average noise window display for channel one.
D4 Average noise window display for channel two.
Monitor average noise.
Note: The average noise level (D3 & D4) is also weighted by the Minimum Signal
Adjustment value. Therefore, if MIN (H value) is increased to be larger than the average
noise level, D3 or D4 will only show the H value instead of the average noise value.
Key ID H: Minimum signal Adjustment (Suggested increment: 20; practical range: 0-200)
Decreasing this number will increase system sensitivity but also at the risk of false alarming.
Vice versa, increasing the value will lower system sensitivity to avoid false alarms caused by
uncontrollable environment noise. There is also an auxiliary POT for RX signal pre-
process sensitivity adjustment (see page 18 and Addendum 1).
There are two antenna channels. Channel 1 is related to vertical orientation and Channel 2 is
related to horizontal orientation. H1 (MIN1) sets the minimum signal of Channel 1, and H2
(MIN2) sets the minimum signal of Channel 2.
Press [MIN] – panel displays as per Figure 7.
Input the parameter number.
Press [CON] to accept the parameter.
Figure 7.1. Antenna Channel 1
Figure 7.2. Antenna Channel 2
H 1 04
H 2 04
Note: See Addendum 1 for
additional tuning instructions.