After confirmation of H1 or H2 values, the panel will display the average noise level weighted
by the minimum signal adjustment for both antenna channels as follows. (See NSE noise
display entry. It’s the same value with D3, D4)
D3 reflects the average noise level weighted by H1 (MIN1) in antenna channel 1.
D4 reflects the average noise value weighted by H2 (MIN2) in antenna channel 2.
Key ID F: TX Off (Default value: 1; valid range: 0-1)
Value Action
0 Turn off Tx
1 Turn on Tx
Press [TX OFF]
Input the parameter number.
Press [CON] to accept the parameter.
Input 0 will turn down the transmitting burst via software control. If system power is reapplied,
the system will return to default state of 1.
Key ID G: Alarm Sound Off
(Default value: 1; valid range: 0-1)
Value Action
0 Turn off alarm sound.
1 Turn on alarm sound.
Press [ARM OFF]
Input the parameter number.
Press [CON] to accept the parameter.
Input 0 will turn down the alarm sound via software control. If system power is reapplied, the
system will return to default state of 1.
Key ID L: Alarm Count Reset
(Default value: 0; valid range: 0-1)
Value Action
0 Initial state.
1 Reset alarm count.
Press [ARM OFF]
Input the parameter number.
Press [CON] to accept the parameter.
Input 1 will reset the alarm count to 0.