Technical Manual
Table Of Contents
- 0. Safety Precautions
- 1. Introduction
- 2. Function of the Coin Selector
- 2.1. Introduction
- 2.2. Programming Connector
- 2.3. Programming of Coins
- 2.4. Coin Selector Output Signals
- 2.5. Coin Blocking
- 2.6. Currencies and Coins
- 2.7. Slave Channels
- 2.8. Coin Return
- 2.9. Safety Features
- 2.10. RFID Card Reader Functionality EMP 500 v7 /CLB
- 2.10.1. Install whcashless App
- 2.10.2. Creation of an Operator Account
- 2.10.3. Setting the Identity of a Coin Selector
- 2.10.4. Getting multiple Operator Keys
- 2.10.5. Setting the Price(s) of a Coin Selector
- 2.10.6. Setting the Price with a Price Setting Key
- 2.10.7. Personalize a CLB Pay Key
- 2.10.8. Loading CLB Pay Key with funds via PayPal
- 2.10.9. Use the CLB Pay Key
- 2.11. Bluetooth Functionality
- 3. The EMP 500 v7 /CLB with Interface 06 – 1 Price Totalizer
- 4.
- 4. Serial Interface
- 5. RS232 Interface
- 6. Coin Selector Label
- 7. Maintenance
- 8. EC Conformation Declaration
- 9. Compliance Statements FCC / ISED for EMP 500 v7 /CLB
- 10. Appendix
- 11. Applications
WH Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 500 v7 /CLB
version 2.7
EMP 500 v7 /CLB subject to technical modification page 23/62
smallest coin value. In this case an error message is shown. This does
not apply to the EMP 500 v7 /CLB with parallel interface.
2.7. Slave Channels
The generation v7 coin selectors also have 16 slave channels (channels
17 to 32) available in addition to the so-called 16 master channels. The
slave channels can have their own settings for the coin parameters and
blocking switches. The slave channels may be assigned arbitrarily to any
master channels. It is even possible to assign multiple slave channels (up
to 16) to a master channel. The slave channel assignment can be done
with wheasy 5 by selecting the “Configuration” pull down – “Currencies
and Coins” and “Slave 17 …24” or “Slave 25 …32”.
The slave channels share the following attributes with the associated
master channel:
• Output line. This means that the slave channel will always signal the
same output line as the associated master channel.
• Coin Value
• Sorting shaft
2.8. Coin Return
The coin selector EMP 500 v7 /CLB has a feature which will measure and
give credit for a coin, and then return it. This feature can be used, for
example with test tokens. It can also be used where certain persons, for
example employees, are to receive benefits without cost (e.g. car
parking).
The setting of this function is also discussed in the wheasy 5 manual in
the “Configuration” chapter, under the sub-heading “Coin Routing”. The
coin return feature is activated by clicking the check box “R”.