Test output lines
Bit 0…7 = output 1…8
activated for 500ms
237
Read input lines
6 Byte
0 = DIP-Switch 1
1 = DIP-Switch 2
2 = DIP-Switch 3
3 = DIP-Switch 4
4 = external blocking
5 = general blocking, reject
236
Read opto states
Bit 0 = acceptance light barrier
Bit 1 = reject light barrier
233
Latch output lines
Bit 0…7 = output 1…8
activated continuously
232
Perform self-check
Answer with ACK, no activities
231
Modify inhibit status
2 Bytes for 16 coins
0 = blocked, 1 = released,
all blocked after power on
230
Request inhibit status
[inhibit 1][inhibit 2]
229
Read buffered credit or
error codes
Buffer with 5 events, see also table
2
must be transmitted at least every
500 ms, otherwise the coin
acceptance will be blocked.
228
Modify master inhibit
0 = coin acceptance blocked
1 = coin acceptance released
227
Request master inhibit
status
[inhibit]
Bit 0 gives general blocking:
0 = blocked, 1 = released
226
Request insertion
counter
[count1][count2][count3]
Number of inserts since power on
225
Request accept counter
[count1][count2][count3]
Number of accepted coins since
power on
222
Modify sorter override
status
2 Byte for 16 coins
cash box redirection,
0 = into cash box, 1 = normal
routing,
After Power on normal routing for
all coins is activated
221
Request sorter override
status
[override1][override2]
Polling of cash box redirecting
216
Request data storage
availability
[000] [000] [000] [000] [000]
no more data storage available
213
Request option flags
[000] Coin Position Format is
used
212
Request coin position
[pos1][pos2] provides inhibit
vector for given coin number
210
Modify sorter path
Changes sorting path for given coin
number. After power on the preset
shaft is active.
209
Request sorter path
Provides sorting path for given coin