Datasheet

Table Of Contents
PN532_C1 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.6 — 28 November 2017
115436 163 of 222
NXP Semiconductors
PN532/C1
Near Field Communication (NFC) controller
8.6.23.23 CIU_RxSel register (6307h)
Selects internal receiver settings.
1000-1011 FeliCa secure IC modulation
1000 RX*
1001 TX
1010 Demodulator comparator output
1011 Reserved
Note: * To have a valid signal the CIU has to be set to the
receiving mode by either the Transceive or Receive
commands. The bit RxMultiple can be used to keep the
CIU in receiving mode
1000-1011 MIFARE secure IC modulation
1100 RX* with RF carrier
1101 TX with RF carrier
1110 RX with RF carrier unfiltered
1111 RX envelope unfiltered
Note: * To have a valid signal the CIU has to be set to the
receiving mode by either the Transceive or Receive
commands. The bit RxMultiple can be used to keep the
CIU in receiving mode
Table 217. Description of CIU_TxSel bits
…continued
Bit Symbol Description
Table 218. CIU_RxSel register (address 6307h) bit allocation
Bit 7 6 5 4 3 2 1 0
Symbol UartSel[1:0] RxWait[5:0]
Reset 10000100
Access R/W R/W R/W R/W R/W R/W R/W R/W
Table 219. Description of CIU_RxSel bits
Bit Symbol Description
7 to 6 UartSel[1:0] Selects the input of the digital part (CL UART) of the CIU
Value Description
00 Constant Low
01 Envelope signal at SIGIN
10 Modulation signal from the internal analog part
11 Modulation signal from SIGIN pin. Only valid for transfer
speeds above 424 kbit/s
5 to 0 RxWait[5:0] After data transmission, the activation of the receiver is delayed for RxWait
bit-clocks. During this ‘frame guard time’ any signal at pin Rx is ignored.
This parameter is ignored by the Receive command. All other commands
(e.g. Transceive, Autocoll, MFAuthent) use this parameter. Depending on
the mode of the CIU, the counter starts differently. In Passive
Communication mode the counters starts with the last modulation of the
transmitted data stream. In Active Communication mode the counter starts
immediately after the external RF field is switched on.