User Manual

12 13
Experiment 5: Rectied AC, dual phase
Connection layout:
Connection summary:
GND clip : 4
Probe tip : 5
Purpose:
ThepurposeofthisexperimentistoshowwhatdualphaserectiedAClookslikeonascopescreen
andtoshowthedifferencewithsinglephaserectiedAC.
How?:
1. Turn on the HPS140 Handheld Pocket Scope (see HPS140 manual for How-To instructions).
2. Place the probe switch “x1/x10” to ‘x1’.
Select 5ms/div and 4V/div.
Astheswitchisstillsettosinglephaserectication,thedisplaywillshowthesametraceas
with experiment 4.
Now,checkwhathappenswhenyouiptheswitchfromsinglephasetodualphaserectication.
Flip the switch back and forward, to clearly see the difference between both settings.
NOTES:
RectiedAC,dualphase
Now,checkwhathappenswhenyouiptheswitchfromsinglephasetodualphaserectication.
Flip the switch back and forward, to clearly see the difference between both settings.
A little theory:
Asyoucansee,the‘interruptions’wehavenoticedwithsinglephaserecticationaregone.Asopposed
tosinglephaserectication,bothhalvesofthesinewaveareused.Insteadofasinglediode,weuse4
diodes to make a ‘diode bridge’
Single diode
Diode bridge
Exercise:
In experiment 3, we have learned how to measure the frequency of a repeating waveform.
Canyoumeasuretheperiodandfrequencyofboththesinglephaseanddualphaserectiedsignal?
(Answer: 10ms/100Hz or 8.33ms/120Hz)
t
t
U
t t
U
UU
RectiedAC,dualphase