User guide

Kinetic Active Series
10
Kinetic 18BA REAR PANEL FEATURES
1. HEAT SINK
2. VOLUME CONTROL
3. INPUT A
4. INPUT B
5. OUTPUT B
6. OUTPUT A
7. POWER SOCKET
8. LIMIT LED
POWER LED
9. POWER SWITCH
10. PHASE SWITCH
11. CROSSOVER
FREQUENCY
CONTROL
Cooling ns for amplier. Do not obstruct.
Adjusts the volume.
TRS Jack and male XLR balanced for INPUT A
TRS Jack and male XLR balanced for INPUT B
Balanced male XLR connector provides output HIGH PASS signal.
Selects the signal type that is routed to the OUTPUT jacks, “THRU”
sends the unprocessed signal to the outputs. “HIGH PASS” lters the
signal at 100Hz to the outputs.
Balanced male XLR connector provides output HIGH PASS signal.
Selects the signal type that is routed to the OUTPUT jacks, “THRU”
sends the unprocessed signal to the outputs. “HIGH PASS” lters the
signal at 100Hz to the outputs.
This is the connection for the IEC AC power connector.
LED indicator illuminates when the signal limiting function is activated.
LED indicator illuminates when the unit is powered up.
Turns the power on and off to the subwoofer amplier module.
Selects the polarity of the signal being sent to the subwoofer.
0
o
selects the signal polarity as it appears at the input.
The 180
o
selection inverts the polarity of the signal.
Adjustable 80Hz to 200Hz.