Owner's manual

WHEATHEART - PORTABLE DRIVE OVER PIT 8. TROUBLESHOOTING
10" & 13"
30686 R0 39
8. Troubleshooting
The following table lists the causes and solutions to some potential problems you
may encounter in operating your hydraulic or electric Portable Pit.
PROBLEM CAUSE SOLUTION
None of the
augers turn.
oil is bypassed to the
wheel lift cylinder
move the circuit selector valve to the centre neutral position
no hydraulic flow is
coming from the power
source
ensure the correct hydraulic lever is engaged
hydraulic power source must be started
electric motor not func-
tioning
check that overheat protection on motor has not been
thrown
check that breaker has not been thrown on supply line
have licensed electrician check wiring
All of the
augers run
backwards.
oil flow is in the wrong
direction
switch direction of flow from hydraulic power source –
either by reversing lever or by switching hose connections
electric motor is wired
backwards
have a licensed electrician check and repair wiring
One, but not
all, augers
have stopped.
drive chain broken or
disconnected
check the drive chain; repair or replace
obstruction in the
auger
identify and remove obstruction
Augers are
noisy
auger shaft bolts are
loose or damaged
tighten or replace bolts
auger shaft is bent repair or replace auger
flighting is damaged
Low material
augering rate.
hydraulic flow is too
low
increase rpm of hydraulic pump
increase flow rate from hydraulic power source
ensure hydraulic system meets flow and pressure specifi-
cation requirements
inadequate material
flow from truck
increase flow of material
uneven material distri-
bution in hopper
keep hopper full
ensure truck is dumping in the centre of the hopper
flow into the auger
intake is restricted
clear grating of obstructions
material too wet or
heavy
unloading rates are for dry grain
flighting is worn repair or replace as required
leaky motor seals service the hydraulic motor
Ramps diffi-
cult to lift.
assist springs not
installed
install springs per Section 3.2.
ramps binding in tabs check for damage; repair as required
obstruction between
ramp and ground
remove obstruction
springs improperly
installed
install springs per Section 3.2.