User Manual

WHEATHEART - REMOTE POWERSWING 5. TROUBLESHOOTING
A232, A233, A234, A235, AND A236 MODELS
30664 R0 17
5. Troubleshooting
Problem Possible Cause Remedy
Hand held trans-
mitter does not
work.
Error with coding the transmitter or receiver.
Verify that coding is correct (see
Section 6. Appendix on page 19).
Contact a Westfield customer ser-
vice representative if problem per-
sists.
Manual switch
does not work.
Incorrect or faulty wiring of the switch.
Verify that wiring to switch is cor-
rect (see Section 2.2. Hydraulic
Configuration on page 10). If
problem persists, replace switch.
Valve only works in
one direction.
Incorrect wiring of the switch. *Incorrect wiring
may also blow the fuse in the junction box.
Verify that valve is wired correctly
(see Section 2.2. Hydraulic Con-
figuration on page 10).
Manual switch and
transmitter do not
work in either
direction.
Power not reaching junction box (white light on
the manual switch does not illuminate).
Remove and insert the 7-pin
connector from the tractor to
ensure a good connection.
Verify the solid connection of
the power supply wire in the
junction box of the Pow-
erswing.
Open the 7-pin connector and
verify that the black wire is
attached securely to the termi-
nal labelled “blue”, and the
white wire to the terminal
labelled “white”.
Power reaching junction box (white light on the
manual switch is illuminated).
Open the junction box and
check the 10-amp fuse.
Replace if there is any doubt
of its condition.
Verify that the manual switch
is wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10). If wired
incorrectly, it can override all
functions.
Verify that the valves are
wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10).