Instruction Manual

6. MAINTENANCE WHEATHEART MANUFACTURING - TRANSFER AUGER
6.1. MAINTENANCE INTERVALS 8”, 10”, & 13”
34 IM2 R2
6.1. MAINTENANCE INTERVALS
Details of service are listed in Section 6.2.
6.2. MAINTENANCE PROCEDURES
6.2.1. VISUAL INSPECTION
Before beginning the visual inspection, chock auger wheels and ensure that all
operators are aware of safety precautions.
When inspecting:
Ensure all guards are in place, and in good working order.
Examine the auger for damage or unusual wear.
Inspect the machine for evidence of oil leaks.
Examine hydraulic hoses and fittings for leaks and cracks.
Be sure all safety decals are in place and are legible.
ELECTRIC DRIVE: Check that drive belts are not frayed or damaged.
Ensure they are properly adjusted and aligned.
Check that the discharge spout and intake area are free of obstructions.
Ensure that intake housing fasteners are properly secured.
Examine all flighting for damage or unusual wear.
Table 6.1
Time Period
Daily
(8000 BU)
Periodically
(40,000 BU)
Annually
(Before Storage)
Annually
(After Storage)
Visually inspect the unit.

Check engine oil level.

Check air filter.
Service belts.
Grease machine.
Check gearbox oil level (gas models).
Clean machine.
Service engine (gas & electric models).