Specifications

NX-8E-CF CONTROL
39
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
ZONES 25-32, PARTITION SELECTION (Segment 1=Zone 25 thru Segment 8=Zone 32)
Segments 1 2 3 4 5 6 7 8
32 21
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
33 21 ZONES 33-40, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 33-40, PARTITION SELECTION (Segment 1=Zone 33 thru Segment 8=Zone 40)
Segments 1 2 3 4 5 6 7 8
34 21
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
35 21 ZONES 41-48, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 41-48, PARTITION SELECTION (Segment 1=Zone 41 thru Segment 8=Zone 48)
Segments 1 2 3 4 5 6 7 8
36 21
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
37 21 SIREN AND SYSTEM SUPERVISION
Segment #1 (Circle numbers to program)
1 = Siren sounds for telephone line cut while armed.
2 = Siren sounds for telephone line cut while disarmed.
3 = Siren blast at arming.
4 = Siren blast at exit delay expiration.
5 = Siren blast at closing kissoff.
6 = Siren sounds during a cross-zone verification time.
7 = Siren sounds for a tamper.
8 = Siren blast one time for keyswitch arming, two times for
disarming.
Segment #2 (Circle numbers to program)
1 = Convert siren driver to voltage out.
2 = Siren sounds for expander trouble (required for U.L.).
3 = Immediate Restore by zone.
4 = Reserved.
5 = Battery missing test performed every 12 seconds.
6 = Manual bell test performed during [r]-[4]-[4] test
function.
7 = Manual communicator test performed during [r]-[4]-[4]
test function.
8 = Box tamper enabled.
Segment #3 (Circle numbers to program)
1 = Box Tamper report enabled.
2 = AC Fail report enabled.
3 = Low Battery report enabled.
4 = Auxiliary power over current report enabled.
5 = Siren supervision report enabled.
6 = Telephone Line Cut report enabled.
7 = Ground Fault Detection report enabled.
8 = Expander trouble report enabled.
Segment #4 (Circle numbers to program)
1 = Failure To Communicate report enabled.
2 = Log Full report enabled.
3 = Autotest report enabled. (required for UL installations)
4 = Start and End Programming report enabled.
5 = Reserved.
6 = Sensor Low Battery report enabled.
7 = Sensor Missing report enabled.
8 = Reserved.
Segment #5 (Circle numbers to program)
1 = Lost Clock service LED enable.
2 = Enables NX-870E siren output to activate for FIRE ONLY.
3 = Disable on-board eight zones.
4 = Enables two trips on the same cross-zone to activate the
alarm.
5 = Disables bypass reports for force armed zones
6 = Silent exit.
7 = Clock uses internal crystal.
8 = Disable Temporal Siren on Fire (Do not disable on UL
listed systems)
Segment #6
1 = Enable 2-wire Smoke Detector.
2 = Reserved.
3 = Enable Zone Activity in Hours (not Days)
4 = Enable Daylight Savings Time (DST)
5 = Reserved
6 = Disable Clean Me report.
7 = Reserved.
8 = Reserved.
Segment #7 - RESERVED