Specifications

NX-8E-CF CONTROL
45
LOC PG DESCRIPTION
DEFAULT
DATA
108 27 PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
Segment #5 RESERVED
PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _
Segment #2 (Exit Time #1) 0 _
Segment #3 (Entry Time #2) 0 _
Segment #4 (Exit Time #2) 0 _
109 27
Segment #5 & #6 RESERVED
110 28 ZONE TYPE 1 ALARM EVENT CODE 8 _
111 28
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
2
3
4
Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour
zone).
Keyswitch zone.
Follower (enable for burg zones that are
instant during non-entry times).
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Segment #2 (Circle numbers to program)
1
2
3
4
Keypad audible on alarm.
Yelping siren on alarm.
Temporal siren on alarm.
Chime.
5
6
7
8
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Segment #3 (Circle numbers to program)
1
2
3
4
Sprinkler Supervisory
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.
5
6
7
8
Dialer Delay zone.
Swinger zone.
Restore reporting.
Reserved
Segment #4 (Circle numbers to program)
1
2
3
4
Zone Activity Monitor.
End of Line Resistor Defeat.
Delays alarm activation 60 seconds.
Zone acts as request to exit input.
5
6
7
8
Reserved.
Reserved.
Reserved.
Reserved.
Segment #5 - Reserved