Specifications

- 9 -
Cautions:
To prevent electric shock or short circuit damage, please ask a qualified technician for installing.
Please use an independent power supply so that the failure caused by the unstable power will not occur.
Metal will block the radio signal. Therefore, stay away from metal when installing the product. Remote control
distance will also become shorter when there is a same frequency signal around.
Adjacent products should be separated at least 3 meters.
If there is a malfunction of the product, please contact the service department.
Functional check list
NO.
Check Items
Detail items Condition Operation(Input) Result
判定 備註
1 HOST
Identification Fail
(Immo Coil)
Power input 12V±0.1V
Place the smart key on the
surface of the Immo. Coil
2.5mm
The smart key need to
remove battery or disconnect
LF antenna
1.Move the smart key away
from sensing area(more
than 5cm)
2.Push power bottom at
300ms
If identification failthe host goes
into standby and do not do
anything.
□OK □NG
Immo sensing
Distance 8cm
2 HOST
Identification Fail
(Immo Coil)
Power input 12V±0.1V
Place the smart key on the
surface of the Immo. Coil
2.5mm
The smart key need to
Move the smart key away
from sensing area(more
than 5cm)
1.Identification after every 3
seconds
2.If identification failsystem will
lock
3.The buzzer sounds for 500ms.
□OK □NG
Remove the
smart key
more than 10
cm.