Owner's Manual
Wall Venting Installation Only
Using a keyhole saw, cut out the retangular wall venting cutout
area.
Using a drill, cut out the power cord hole cutout area and the
two mounting nut holes. This step is for all venting installations.
Drill Holes in Rear Wall
In addition to being installed on at least 1 wall stud, the
mounting plate must attach to the wall at both end holes. If the
end holes are not over wall studs, use two 3/16-24 x 3"
round head bolts with toggle nuts; if 1 end hole is over a wall
stud, use 1 lag screw and one 3/16-24 x 3" round-head bolt with
toggle nut; or if both end holes are over wall studs, use 2 lag
Installation for No Wall Studs at End Holes
(Figures 1 and 2)
1. Drill 5/8" (1.6 cm) holes through the wall at both end holes
marked in Step 3 of the “Mark Rear Wall.”
2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s)
Wall Stud(s)” section.
Installation for Wall Stud at One End Hole (Figure 3)
1. Drill a 3/16" (5 mm) hole into the wall stud at the end hole
marked in Step 3 of the “Mark Rear Wall.”
2. If installing on a second wall stud, drill a 3/16" (5 mm) hole
into the wall stud at the other hole marked in Step 6 of
the“Mark Rear Wall.” Refer to Figure 3 in “Possible Wall Stud
3. Drill a 5/8" (1.6 cm) hole through the wall at the other end
hole.
Installation for Wall Studs at Both End Holes
(Figure 4)
1. Drill 3/16" (5 mm) holes into the studs at the end holes
marked in Step 3 of the “Mark Rear Wall.”
Attach Mounting Plate to Wall
“Locate Wall Stud(s)” section.
No Wall Studs at End Holes (Figures 1 and 2)
NOTE: The mounting plate must be secured to the wall on at
least 1 wall stud as well as at both ends.
1. With the support tabs of the mounting plate facing forward,
insert 3/16-24 x 3" round-head bolts through both end holes
of mounting plate.
NOTE: If upper cabinet is metal, the supply cord bushing needs
to be installed around the supply cord hole as shown.
A
B
A. Metal cabinet
B. Power supply cord bushing
10
A
Drill Holes in Rear Wall and Upper Cabinet
Roof Venting Installation Only
Using a keyhole saw, cut out the retangular roof venting cutout
area.
A. Wall Venting Area
A
A. Upper Cabinet Area
A
A. Power Cord Hole
B. Mounting Nut Holes
1.
2. Drill 3/8" (10 mm) holes at points “D” and “E” on the
template. These are for two 1/4-20 x 3" bolts and washers
used to secure the microwave oven to the upper cabinet.
B
A
A. Wall Centerline
B. Bottom Edge of Mounting Plate
C. Mouting Plate Bottom Line
D. Center Mark
B
C
Placing the mounting plate against the wall, make sure the
center mark align with the vertical wall centerline, and
make sure the mounting plate bottom edge align with the
mounting plate bottom line.
D
1.
2.
Secure the mounting plate to the wall at both end holes
drilled into the wall studs and/or drywall using either
3/16-24 x 3" round-head bolts and toggle nuts or 1/4 x 2"
lag screws.