Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See the “Electrical Requirements” section.
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop
below.
** 36" (91.4 cm) is recommended for 72" (182.8 cm) installation
height.
*** for the minimum 12" (30.5 cm) cabinets, the door is not ush
with the cabinet outside.
**** for 13" (33 cm) cabinets, needs a special nail for installation,
see xxx section.
Electrical Requirements
Observe all governing codes and ordinances.
Required:
■ A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a
fuse or circuit breaker
Recommended:
■ A time-delay fuse or time-delay circuit breaker
■ A separate circuit serving only this microwave oven
A. 2" x 4" (5.1 x 10.2 cm) wall stud
B. Grounded 3 prong outlet
12.75" (32.4 cm) flush
12" (30.5 cm) min.***
13" (33 cm) max. ****
30"
(76.2 cm)
min.
A B
upper cabinet and
side cabinet depth
30"
(76.2 cm)
typical*
36"
(91.4 cm)
recommended**
66" (167.6 cm)
minimum
72”(182.8 cm)
recommended
Mounting plate
Bump out mounting bracket
13"
DEEPER
15"
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Note: If cabinets are deeper than 13" (33 cm), use the bump out
mounting kit replacing the mounting plate from the wall. The
bump out mounting kit (part# W12345678) is not provided. To
order, see the “Online Ordering Information” section of the
Quick Start Guide.
Mounting plate
12"
DEEPER
12.75"
12.75"
DEEPER
13"