Installation Instructions

A single-phase, 6OHz.
AC only, electrical supFjly is
required on a separate circuit. A
15amp. time-delay fuse or circuit
breaker is required. Copper wire
(#14-gauge) is required.
The model and serial label is
located behind the front panel
on the base flange.
Specific electrical requirements
are listed in the chart. Follow the
requirements for the type of plug
on the power supply cord.
Wiring
requirements
r
Plug Type A 1
Plug Type B
J-prong
grounding
plug
I
l/4’ blade
Dower supply cord
grounding prong
1 15volt -
230/2oa
~0tt -
103.5~ min., 197.6~ min.,
126.5~
max.
23%
max.
7Samp
12-amp rating
ratings or less
or less - use a
- a double
single outlet
outlet is and a separate
acceptable.
circuit.
7.6 through
I2-amp ratings
- use only a
;ingle outlet and
;eparate circuit.
Recommended grounding
method
Do Not, under any circumstances,
remove the power supply cord
grounding prong.
For your personal safety, this
appliance must be grounded.
This appliance is equipped with a
power supply cord having a
3-prong grounding plug. To
minimize possible shock hazard.
the cord must be plugged into a
mating, 3-prong grounding-type
wall receptacle, grounded in
accordance with the National
Electrical Code, ANSI/NFPA
70-latest edition, and local codes
and ordinances. If a mating wall
receptacle is not available, it is
the personal responsibility and
obligation of the customer to
have a properly grounded,
3-prong wall receptacle installed
by a qualified electrician.
Now start...
with air conditioner in room
where it will be installed.
It is the customer’s responsibility
and obligation to have this
product installed by a qualified
technician familiar with through-
the-wall room air conditioner
installations.
Check the air conditioner model
number on the model/serial label
located behind the front panel on
the base flange.
If the air conditioner model num-
ber starts with letters ACU, it must
be installed into on air conditioner
sleeve. It will fit into a Whirlpool
sleeve, Model? AOW22W2, or a
comparable sleeve that is at least
19” deep. See THROUGH-THE-WALL
SLEEVE INSTALLATION on bock
cover.
If the air conditioner mO=del num-
ber starts with letters other than
ACU, instoll according to
THROUGH-THE-WALL INSTALLATICI\I
Appropriate
header if required
plaster
t
alternate
construction
for plaster
frame
construction
Appropriate
header if required
trim*% lintel
frame
thickness
alternate
construction
or plaster
e
brick veneer to ‘rame
construction
1
When using a wood, metal
n
or plastic molding, the
frame should line up with the
inside wall. If the plastered wall
is to be flush with the cabinet
and no molding is used, the
frame must be set l/2-inch into
the wall.
SS
wall
Dimension depends
on wall thickness
and type of molding.
2
Cut opening through the
n
wall. Remove insulation.
3
Use l-inch or heavier
n
lumber for wood frome.
Measure depth of wall opening
and frame. Apply wood
preservative to the outside,
exposed surface.
Page 3