Installation

5
Wall standpipe drain system
Laundry tub drain system
Minimum capacity: 76 L (20 gal.).
IMPORTANT:
n
Top of laundry tub must be at least 990 mm (39") above oor;
install no higher than 1.22 m (48") from bottom of washer.
n
To avoid siphoning, no more than 114 mm (4.5") of drain hose
should be inside standpipe or below the top of wash tub.
Secure drain hose with cable tie.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. To order, please contact the dealer from
whom you purchased your washer or an authorized service
company. Minimum siphon break: 710 mm (28") from bottom
of washer. (Additional hoses may be needed.)
See requirements for oor standpipe drain system.
Electric Requirements
EARTHING INSTRUCTIONS
This washer must be earthed. In the event of a malfunction
or breakdown, earthing will reduce the risk of electric
shock by providing a path of least resistance for electric
current. This washer is equipped with a cord having an
equipment-earthing conductor and an earthing plug. The
plug must be plugged into an appropriate outlet that is
properly installed and earthed in accordance with all local
codes and ordinances.
WARNING: Improper connection of the equipment-
earthing conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly earthed.
Do not modify the plug provided with the appliance – if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
n
A 220–240 V, 50/60 Hz., AC-only, 10-amp, fused electrical supply
is required. A time-delay fuse or circuit breaker is recommended.
It is recommended that a separate circuit breaker serving only this
appliance be provided.
n
This washer is equipped with a power supply cord having
an earthing plug. If the supply cord is damaged, it must be
replaced by the manufacturer, a qualied service agent,
or other qualied person to avoid a hazard.
n
To minimize possible shock hazard, the cord must be plugged
into a mating, earthing-type outlet, earthed in accordance with
local codes and ordinances. If a mating outlet is not available,
it is the personal responsibility and obligation of the customer
to have the properly earthed outlet installed by a qualied
electrician.
n
If codes permit and a separate earth wire is used, it is
recommended that a qualied electrician determine that
the earth path is adequate.
n
Do not earth to a gas pipe.
n
Check with a qualied electrician if you are not sure the
washer is properly earthed.
n
Do not have a fuse in the neutral or earth circuit.
n
When in the installed position, the mains plug must be
accessible for disconnection.
n
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualied persons
in order to avoid a hazard.
Drain System
Drain system can be installed using a oor drain, wall standpipe,
oor standpipe, or laundry tub. Select the method you need.
Minimum diameter for a standpipe drain: 51 mm (2"). Minimum
carry-away capacity: 64 L (17 gal.) per minute. Top of standpipe
must be at least 990 mm (39") high; install no higher than
1.22 m (48") from bottom of washer. If you must install higher
than 1.22 m (48"), you will need a sump pump system.
Floor standpipe drain system
114 mm
(4.5")
114 mm
(4.5")
990 mm
(39")
114 mm
(4.5")
990 mm
(39")