Instruction for Use

ENGLISH 21
Insert part R (rawlplug) into holes F and
screw hook G into part R (Fig. 3).
2x
F
R
G
Fig. 3
Secure the chain to hook G as shown in
Fig. 4 position C.
2x
G
C
C
Fig. 4
INJECTORS TABLE
i
Class appliance: 1
Appliance Category II2H3+
Type of gas
used
Type of
burner
Injector
marking
Nominal
heating
capacity
Nominal
consumption
Reduced
heat
capacity
Gas pressure
mbar
kW kW min. rated max.
Natural gas
(Methane)
G20
triple ring
rapid
semirapid
auxiliary
13 0
115
97
72
3.60
3.00
1.75
1.00
343 l/h
286 l/h
167 l/h
95 l/h
1.30
0.75
0.48
0.33
17 20 25
Liquid
petroleum
gas (cylinder)
G30
triple ring
rapid
semirapid
auxiliary
96
85
65
50
3.60
3.00
1.75
1.00
262 g/h
219 g/h
128 g/h
73 g/h
1.30
0.75
0.48
0.33
20 28-30 35
Liquid
petroleum
gas (cylinder)
G31
triple ring
rapid
semirapid
auxiliary
96
85
65
50
3.60
3.00
1.75
1.00
258 g/h
215 g/h
124 g/h
69 g/h
1.30
0.75
0.48
0.33
25 37 45
Type of gas used Model
conīƒ€guration
Total nominal
heating capacity
kW
Total nominal
consumption
Air necessary (m
3
)
for combustion of
1 m
3
of gas
G20 20 mbar 5 burners 11.10 1058 l/h 21.6
G30 28-30 mbar 5 burners 11.10 810 g/h 21.6
G31 37 mbar 5 burners 11 .10 790 g/h 21.6
ELECTRICAL POWER SUPPLY: 230 V ~ 50 Hz