Gas connection
For information regarding gas connection
instructions, see the injectors table and the
“standard”relevanttoyourcountry.
The gas supply system must comply with
current local regulations.
The appliance must be connected to the
gas supply or gas bottle by means of a rigid
copper, steel pipe or rubber hose based on
local regulation (see gas connection table).
The maximum length of the hose is 2 m.
The hose must be connected directly to the
outletconnector(Fig.1),afterrstofall
ensuring you remove any extension cable
ttedtoyourappliance.
Fig. 1
i
IMPORTANT: when using a rubber
hose, it must be installed in such a way
as not to be in contact with hot parts on the
rear of the appliance or kitchen. It must pass
through an area free of any hindrances and
in a place where it can be inspected along
its entire length (Fig. 2).
Fig. 2
When the appliance is connected to the gas
supply, use soapy water to check for gas
leaks.
The rubber hose must be connected as
shown in Fig. 3, 4 and 5, in compliance with
local applicable regulations
FOR FRANCE ONLY: do not install the
conicaltting(B)suppliedontheappliance.
A
B
ISO 228-1
ISO 7-1
Fig. 3
Natural gas
Use outlet connector GN for natural gas or
a propane-air mixture.
The rubber hose must be connected to the
outlet connector and secured using hose
clamp (C) (Fig. 4).
C
Fig. 4