Installation Guide

2 E-5287134
FIGURE 1
"63"81
8"
1-1/2"
HOLE
Outlet Location
1. The receptacle outlet should be within a reasonable
distance of the dishwasher in order for the cord to reach
without being strained. See dotted lines in figure 1.
IMPORTANT: Do not use an extension cord.
2. If necessary, cut a 1-1/2(4cm) diameter hole in either
of the cabinet side walls to allow the new cord to pass
through. See figure 1.
3. If the cabinet side walls are wood, sand the edge of the
hole until smooth. If the side wall is metal, install the
protective grommet sup
plied in this kit.
To mount the new assembly
1. Disconnect power or unplug dishwasher.
2. Remove access panel and terminal box cover.
3. Install metal strain relief in hole in the back of terminal
box. See figure 2.
4. Install the wires (opposite the plug end) of the cord into
the terminal box through the metal strain relief. Tighten
clamp or connector on power cord using phillips
screwdriver.
5. Connect the white and black wires of the power supply
cord to the white and black wires in the terminal
box
using wire connectors supply. See figure 3.
6. Ground wire connection:
6a. Units with grounding bolts.
Locate the power cord green grounding wire and remove
the ring terminal. Remove ½” of the outer green wire
jacket to expose the inner wire. Mate this wire to the
remaining green wire from your dishwasher.
Use remaining wire nut to complete the connection
(see helpful tip for proper connection technique.)
7. Replace the terminal box cover.
8. Dishwasher should be plugged in or cord passed through
hole in the cabinet before access panel is reinstalled.
I MPORTANT: The strain relief MUST BE USED
to
prevent the power cord wires from being pulled out of
the terminal box accidentally.
9. Replace the access panel.
10. Reconnect power or plug in dishwasher.
STRAIN RELIEF
POWER CORD
POWER SUPPLY
CORD
TERMINAL BOX
W
B
TERMINAL BOX
COVER
APPLIANCE WIRING
HARNESS
GREEN GROUND
WIRE
GROUNDING
BOLT AND NUT
WIRE
CONNECTOR
APPLIANCE WIRING HARNESS
FIGURE 3
FIGURE 2
HELPFUL TIP:
Select the proper size twist-on
connectors to connect your
household wiring to 16-gauge
dishwasher wiring
Insert wire ends into twist-on
connector. Do not pre-twist bare
wire.
Twist connector.
Gently tug on wires to be sure both
are secured.
STRAIN RELIEF
B
W
GREEN W/YELLOW
STRIPE
6b. Units without grounding bolts.
Remove the grounding bolt and place the ring terminal
of the green ground wire on the power cord over the
bolt. Reattach and tighten the green bolt. See figure 3.