IMPORTANT: Do not overtighten or use tape or sealants on valve
when attaching to faucets or machine. Damage can result. Attach
the hose labeled hot to hot water faucet. Screw on coupling by
hand until it is seated on washer. Use adjustable pliers to tighten
couplings an additional two-thirds turn. Repeat this step with the
hose labeled cold for the cold water faucet. Both hoses must be
connected for machine to work properly.
Clear water lines
Run water for a few seconds through hoses into a laundry tub,
drainpipe, or bucket to avoid clogs. Water should run until clear.
Connect inlet hoses to Machine
IMPORTANT: To reduce risk of hose failure, replace the hoses
every 5 years. Record hose installation or replacement dates for
future reference.
n Do not overtighten hose or use tape or sealants on the
valve. Damage to the valves can result.
n Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
Attach hot water hose to hot water inlet valve. Screw coupling by
hand until it is snug. Use adjustable pliers to tighten couplings an
additional two-thirds turn. Repeat with cold water inlet valve.
Check for leaks
Slowly turn on water faucets to check for leaks. A small amount of
water may enter machine. It will drain later.
Secure drain hose
Secure drain hose to laundry tub leg, drain standpipe, or inlet
hoses for wall standpipe with cable tie or beaded tie strap. It is the
responsibility of the installer to install and secure the drain hose in
to the provided plumbing/drain in a manner that will avoid the drain
hose coming out of or leaking from the plumbing/drain.
Level All-In-One Washer Dryer
IMPORTANT: Leveling your machine properly reduces excess
noise and vibration.
Check levelness of machine
Remove cardboard from beneath machine. Place a level on top
edges of machine, checking each side and front. If not level, tip
machine and adjust feet up or down as shown in Adjust leveling
feet” and “Tighten leveling feet”, repeating as necessary.
4.5"
(114 mm)
4.5"
(114 mm)
Laundry Tub
4.5"
(114 mm)
Standpipe
4.5"
(113 mm)
4.5"
(114 mm)
Wall
Place level here