Use & care guide

8
Gas conversion
Gas conversions (from Natural gas to L.P.
gas; or from L.P. gas to Natural gas) must
be done by a qualified installer.
L.P. gas conversion
1. Complete installation Steps 1-9
(Pages 5-6) before converting cooktop to
L.P. gas. Check that the manual shutoff
valve in the gas supply line has been
turned off.
4. Remove burner grates, burners
and screws. Lift cooktop. NOTE: There is
no cooktop support rod.
5. Cooktop burners:
a. Check that all control knobs are in the
OFF position and remove the knobs.
b. Remove the control panel. (See Step
15a, Page 6.)
6. Oven burner:
a. Carefully pull oven burner away from
back wall of oven just enough to access
the orifice spud located behind the
burners air shutter.
b. Locate L.P. gas orifice spud stamped
“56” in literature package supplied with
range.
c. Use a 3/8” combination wrench and
remove the natural gas orifice spud.
Install the number “56” L.P. gas spud.
Place natural gas oven burner spud in
plastic parts bag along with natural gas
cooktop burner spuds for future use and
keep with literature package.
d. Reinstall the oven burner.
2. Open broiler drawer and remove
broiler pan. The pressure regulator is
located in the back right hand corner of
the broiler compartment.
DO NOT REMOVE THE PRESSURE
REGULATOR.
3. Pressure
regulator:
Remove the cap
from the
pressure
regulator. Turn
the cap over so
that LP is visible. Replace the cap.
burner
screw
Fire Hazard
Shut off gas supply line valve.
Make all conversions before
turning gas supply valve back on.
Failure to follow these instructions
can result in explosion, fire or
other injury.
WARNING
viewed from
inside broiler
compartment
screws
orifice
tube
assemblies
c. Remove the
screws holding
burner tube
assemblies to
bracket and
carefully move
tubes back away
from orifice.
d. Locate L.P. gas orifice spuds for top
burners in literature package included
with the range. L.P. gas spuds are
stamped “65”. Remove Natural gas orifice
spuds using a 3/8" combination wrench.
Install L.P. gas orifice spuds to replace the
Natural gas orifice spuds.
orifice spuds
NAT
L.P.
L.R.
L.F.
R.R.
R.F.
gas
manifold
notches
Remove and replace
orifice spuds.
Note: Burner tube and
brackets not shown.
“65”
“65”
“65”
“65”
Place Natural gas orifice spuds in plastic
parts bag for future use and keep with
literature package.
Reinstall burner tube assemblies and
tighten screws securely.
e. Lower cooktop. Reinstall screws to
secure burner tube assemblies to
cooktop and tighten securely. Reinstall
burners and burner grates.
Do not reinstall control panel or knobs.
They will be reinstalled at Step 11, Page 9.
oven burner
orifice behind
air shutter
8.Turn manual shutoff valve in gas
supply line on. If “Gas connection” Steps
10-17 on Pages 5-6 were not completed,
complete them now.
L.P. oven orifice
spud stamped
with "56"
7. Locate selector key on oven
thermostat and turn clockwise to the L.P.
position.
L
P
N
A
T
thermostat
gas
manifold
selector
key