Dimensions Guide

Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10837635A
05/23/2016
Page 2 of 2
ELECTRICAL REQUIREMENTS
IMPORTANT: The cooktop must be electrically grounded in accordance
with local codes and ordinances, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code,
CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended
that a qualified electrical installer determine that the ground path is
adequate.
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It
is recommended that a separate circuit serving only this cooktop be
provided.
CABINET REQUIREMENTS
IMPORTANT: If installing a range hood or microwave hood combination
above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop
surface.
NOTES: After making the countertop cutout, some installations may
require notching down the base cabinet side walls to clear the burner
box. To avoid this modification, use a base cabinet with sidewalls wider
than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base cabinet
is required. The drawer depth may need to be shortened to avoid
interfering with the regulator.
C
B
A
E
F
H
I
G
K
L
D
J
A. 24" (61 cm) minimum - 26" (68 cm) maximum distance
between overhead cabinets
B. 13" (33 cm) minimum recommended upper cabinet depth
C. 30" (75 cm) minimum combustible area above countertop
(shown by dashed box above)
D. 18
29
/
32
" (48 cm)
E. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout.
F. 22
3
/
64
" (56 cm)
G. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended.
H. 4" (10 cm) minimum distance to nearest left and right-side
combustible surface
I. 2
7
/
8
" (7 cm) minimum distance to rear combustible surface
J. 20
1
/
2
" (52 cm) minimum clearance from upper cabinet
to countertop within minimum horizontal clearances to
cooktop
K. 30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or
metal cabinet is covered by not less than
1
/
4
" [0.6 cm] flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024"
[0.06 cm] aluminum or 0.020" [0.05 cm] copper)
L. 25
5
/
8
" (65.09 cm) minimum countertop depth is required.