Instruction for Use

P/B3L2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G25
Power Burner
141A
3.50 388 l/h 1.55
20 25 30
Rapid
132 C
3.00 332 l/h 0.60
Semi-rapid
100
1.75 194 l/h 0.35
Auxiliary
78 B
1.00 111 l/h 0.35
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Power Burner
93 P
3.50 254 g/h1.55
25 30 35
Rapid
86
3.00 218 g/h0.60
Semi-rapid
65
1.75 127 g/h0.35
Auxiliary
50
1.00 73 g/h0.35
Type of gas used Model conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G25 25 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX 11.001219 l/h8.187
G30/G31 30 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX11.00 799 g/h 30.94
ELECTRIC SUPPLY: 230 V ~ 50 Hz
WOK ADAPTER (if present)
The WOK adapter has to be used only on the Power Burner [with multiple crown]
Appearence of your product can be slightly different from the drawing.